期刊文献+

LiF热释光剂量计对49.3MeV/u ^(12)C离子束辐射的剂量响应初步研究 被引量:1

Preliminary research on dose repe of LIF thermoluminescence dosimeter to irradiation of 49.3MeV/u carbon ion beam
下载PDF
导出
摘要 用LiF(M,Ti)热释光剂量计测量了兰州重离子研究装置提供的49.3MeV/u12C离子束辐射的剂量响应.结果发现,离子注量在1×107-2×108/cm2时,LiF对碳离子束的剂量响应效率η变化幅度不大,平均值为57%。提示LiF可用于一定离子注量范围内吸收剂量的测量,并且该结果与德国GSI通过重离子径迹结构理论模型计算得到的热释光剂量计对50MeV/u12C离子束的η=54%基本一致。 LiF(Mg,Ti) thermoluminescence dosimeter (TLD) was applied to measure dose response to irradiation of 49.3MeV/u 12C ion beam supplied by HIRFL. Moderate variance of dose-response efficiency was found when particle fluence increases from 1×107 to 2×10 8/cm2 . The average dose-response efficiency 57% was obtained. This phenomenon implies that LiF can be used to measure absorbed dose in a certain range of particle fluence . Moreover, the result is in a good agreement with the calculated dose-response efficiency 54% to 50MeV/u 12C ion beam, which was predicted by the model of heavy-ion track structure at GSI, Germany.
出处 《核技术》 CAS CSCD 北大核心 1999年第10期636-639,共4页 Nuclear Techniques
基金 国家科委攀登计划(B)项目!950603 甘肃省自然科学基金!A57
关键词 热释光剂量 剂量响应效率 剂量响应 氟化锂 Thermoluminescence dosimeter, Dose-response efficiency, Dose response, Heavy ion beam