期刊文献+

玻璃球的耐候性试验研究

Experimental research on the weathering resistance of glass ball
下载PDF
导出
摘要 介绍感温动作元件玻璃球的耐候性试验测试方法。应用静态动作温度试验方法测试45只喷头,分析使用时间、工况的不同和工作液的变化对性能的影响。公称动作温度不大于79℃的玻璃球采用水浴测量;公称动作温度79℃以上的玻璃球采用油浴测量。玻璃泡工作液的变化仅能作为使用时间的判定;玻璃球工作液颜色没有变化时玻璃球性能也可能已经改变。 The experiment method of weathering resistance of glass ball in temperature-sensing element was introduced.The static acting temperature testing method was used and 45 sprinklers were tested in liquid.The effect of time in using,scenario and change of working solution to using performance were analyzed.The glass ball which nominal operating temperature is not higher than 79 ℃ were tested in water and the glass balls which nominal operating temperature is higher than 79 ℃ were tested in oil.The time in usage only can be determined by change of working solution in glass ball.The performance of glass ball may have changed even the color of working solution did not change.
出处 《消防科学与技术》 CAS 北大核心 2011年第1期43-45,共3页 Fire Science and Technology
关键词 耐候性 感温动作元件 工作液 weather resistance temperature-sensing act element working solution
  • 相关文献

参考文献5

二级参考文献34

  • 1王建文,安春辉,赵世明.自动喷水灭火系统喷头最大间距辨析[J].消防科学与技术,2004,23(5):462-464. 被引量:1
  • 2张勤,范海英.肋梁楼板无吊顶场所自动喷水灭火系统设计[J].给水排水,2006,32(9):63-65. 被引量:2
  • 3Edward K Budnick, Harold E Nelson. Simplified Fire Growth Calculations, Fire Protection Handbook, 18th Edition[M]. National Fire Protection Association, Batterymarch Park,Quincy, MA,1997. 被引量:1
  • 4DG08-88-2000,民用建筑防排烟技术规程[S]. 被引量:1
  • 5Kevin B McGranttan, Glenn P Forney, Jason E Floyd, et al. Fire dynamics simulator-user's guide[M]. National Institute of Stands and Technology, Building and Fire Research Laboratory, 2002. 被引量:1
  • 6Baum H R, K B McGrattan, R G Rehm. Three dimensional simulations of fire Plumedynamics [M]. Fire Safety Science Proceedings of the fifth international symposium:511-522. 被引量:1
  • 7Soonil Nam. Actuation of sprinklers at high ceiling clearance faeilities [J]. Fire Safety Journal, 2004,39(7) :619-642. 被引量:1
  • 8Nam S, Braga A, Kung H C, et al. Fire protection for non-storage occupancies with high ceiling clearances [C]. 7th International Symposium on Fire Safety Science, June 2002 : 16 - 21. 被引量:1
  • 9公安部天津消防研究所.火灾增长分析的原则和方法[R].国家十五重点科技攻关项目专题四研究报告,2004. 被引量:1
  • 10NFPA 13,Standard for the Installation of Sprinkler Systems[S]. 被引量:1