地下公交站火灾烟气运动数值模拟 被引量:7

Numerical simulation of smoke control in underground bus station
下载PDF
导出
摘要 阐述地下公交站的现状及火灾危险性。利用FDS软件对不同喷淋和排烟设置下的烟气运动进行模拟,分析烟气运动规律及喷淋和排烟在烟气控制方面的作用。结果表明:靠近外墙体的监测点较之远离外墙体的监测点温度上升更快,能见度下降也更快;能见度通常领先其他火灾参数到达危险状态;喷淋系统在控制烟气蔓延上具有显著作用;喷淋失效时,单凭排烟量不足以阻挡烟气下降。 The status and fire risk of underground bus station were expatiated.Based on FDS,the smoke movement in different conditions of sprinkler and exhaust were simulated.The smoke movement in underground bus station and smoke control effects of the sprinkler and exhaust were discussed.Results showed that: temperature increases faster at the location near the wall than that far from the wall,while the visibility decreases faster too;visibility reaches the risk threshold first;sprinkler plays an important role in the smoke control;smoke exhaust can't stop the smoke from lowering when the sprinkler fails.
出处 《消防科学与技术》 CAS 北大核心 2011年第1期23-25,共3页 Fire Science and Technology
关键词 地下公交站 烟气控制 数值模拟 underground bus station smoke control numerical simulation
  • 相关文献

参考文献8

  • 1许超..哈尔滨新纪元地下商业街火灾烟气的控制与人员疏散[D].哈尔滨工程大学,2008:
  • 2邵力权.浅谈地下建筑防火设计[J].福建建设科技,2007(1):66-67. 被引量:6
  • 3李引擎.建筑防火性能化设计[M].北京:化学工业出版社,2002. 被引量:2
  • 4NFPA 92B-2009,Smoke management system in malls, atria, and large areas[S]. 被引量:1
  • 5ISO 2003 TC92/SC4N 18 Rev5,Fire safety engineering. Require ments governing algebraic formulas. Vent flows[S]. 被引量:1
  • 6公安部天津消防研究所.火灾增长分析的原则和方法[R].国家十五重点科技攻关项目专题四研究报告,2004. 被引量:2
  • 7姚浩伟,梁栋,胡志俭.高层建筑楼梯间烟气控制FDS研究应用[c].第十届中国科协论文集,2009. 被引量:1
  • 8GB50067-97.汽车库、修车库、停车场设计防火规范[S].[S].,.. 被引量:148