通过对清华大学大型公共建筑用电分项计量数据库中大量数据的统计分析,指出大型公共建筑中变压器运行负荷率低的现状,探讨调整单位建筑面积电气设计容量的可行性和重要性。
Based on the statistical analysis of large numbers of data in the electricity sub-metering database sytem of large-scale public buildings in Tsinghua University,the actuality of low operation load rate of transformers in large-scale public buildings is pointed out and the feasibility and importance of adjusting electrical design capacity of the unit floor area is discussed.
出处
《建筑电气》
2011年第1期11-15,共5页
Building Electricity
关键词
电气设计容量
节能
变压器负荷率
大型公共建筑
Electrical design capacity Energy conservation Load rate of transformer Large-scale public buildings