期刊文献+

滴速式输液泵/控制器准确性测试系统研究 被引量:6

Study of drip rate infusion pump/controller accuracy testing system
下载PDF
导出
摘要 为确保医疗工作中不同类型患者点滴输液的安全,设计一种基于采集卡MP451的输液控制精度的红外检测系统.阐述了系统的硬件组成、工作原理和软件设计.实验测试结果表明:这种红外检测系统可以实现对医用输液状况的实时监测,操作简便,能满足目前标准要求的检测精度. To ensure the safety of patients with different types in the medical trement works,design an infrared testing system which can control the transfusion accuracy based on MP451 acquisition card.This paper expounds the system's hardware composition,working principle and software design.The system can realize the infusion of medical condition monitoring in real time,and the experimental results show that this system has excellent performance,convenient operation and meet the requirements of precision.
出处 《上海理工大学学报》 CAS 北大核心 2010年第6期581-583,共3页 Journal of University of Shanghai For Science and Technology
关键词 医疗器械 输液泵 光电检测 medical apparatus and instruments infusion pump photoelectric detection