期刊文献+

双源CT头颈部CTA扫描参数优化的研究 被引量:4

Optimal scanning parameters of dual resource CT angiography in intracranial and cervical arteries
下载PDF
导出
摘要 目的探讨双源CT头颈部联合动脉成像时调整螺距及阈值,改变触发点,对颅内血管显影的影响。方法 100例临床怀疑头颈部血管病变的患者,分为A、B两组行头颈部动脉螺旋CT血管造影(Computed Tomography Angiography,CTA)扫描。A组采用螺距0.9,触发点设在主动脉弓升部,阈值为50 HU;B组采用螺距0.7,触发点设在颈动脉主干,阈值为100HU,比较两组的动脉成像质量和颅内静脉显示情况。所得原始数据均行多平面重组(MPR)、最大密度投影(M IP)、容积再现(VRT)重组,将图像质量分为4级。结果 A组显示双侧颈动脉、椎动脉和颅内动脉与B组图像差异无统计学意义(P>0.05),而显示颅内静脉两组差异有统计学意义(P<0.05),A组对防止颅内静脉的过度显影优于B组。结论双源CT头颈部联合扫描CTA选择合适的参数对获得较好的图像和降低颅内静脉显影是非常重要的。 Objective To study the optimal scanning parameters in dual resource CT angiography (CTA) in intracranial and cervical arteries. Methods One hundred patients suspected intracranial and cervical arteries disease were randomly divided into two groups to receive CTA scan, including group A with pitch 0. 9 and trigger point on descending aorta near aorta arch and group B with pitch O. 7 and trigger point on common carotid artery. Image quality between the two groups was compared. Reconstruction techniqhes including muhiplanar reconstruction (MPR) ,volume rendering ( VR) and maximum intensity projection (MIP) were used and image quality was evaluated. Results Group A was significantly superior to group B in the detection of intracranial vein ( P 〈 0. 05 ). There were no significant differences between the two groups in the detection of bilateral carotid artery, vertebral artery and intraeranial artery ( P 〉 0. 05 ). Conclusion Selection of optimal scanning parameters plays an important role in dual resource CTA in intracranial and cervical arteries.
出处 《实用医院临床杂志》 2011年第1期49-52,共4页 Practical Journal of Clinical Medicine
关键词 双源CT 头颈部 动脉 扫描参数 血管造影 Dual resource CT Head and neck Artery Tomography Scanning parameters
  • 相关文献

参考文献10

二级参考文献26

  • 1郑钧正,岳保荣,李述唐,王琪,张建峰.我国“九五”期间X射线诊断的医疗照射频率水平[J].中华放射医学与防护杂志,2001(S1):20-24. 被引量:69
  • 2柳澄,秦维昌.多层螺旋CT(一)[J].医学影像学杂志,2000,10(3):194-195. 被引量:42
  • 3肖平,谭理连,李扬彬,曹卫国,李树欣,周少萍.16层螺旋CT触发技术在颈部动脉CTA中的临床应用[J].放射学实践,2006,21(5):520-522. 被引量:10
  • 4Fox AJ. How to measure carotid stenosis [ J ]. Radiology, 1993,186 ( 3 ) : 316-318. 被引量:1
  • 5Sameshima T, Fur ami S, Morita Y, et al. Clinical usetulness ol and problems with three-dimensional CT angiography for the evaluation of arteriosclerotic stenosis of the carotid artery: comparison with conventional angiography MRA and ultrasound sonography [ J ]. Surg Neurol, 1999,51 (3) :301-309. 被引量:1
  • 6Mayberg MR. Carotid artery stenosis [ J ]. J Neurosurg, 2003,99 ( 2 ) : 225 -227. 被引量:1
  • 7Hirai T, Korogi Y, Ono K, et al. Preoperative evaluation of intracranial aneurysms: usefulness of intraarterial 3 D CT angiography and conventional angiography with a combined unit--initial experience [ J ]. Radiology, 2001,220 ( 2 ) :499-505. 被引量:1
  • 8Teksam M, McKinney A,Casey S,et al. Multi-section CT angiography for detection of cerebral aneurysms[ J ]. AJNR Am J Neuroradiol,2004,25 (9) : 1485-1492. 被引量:1
  • 9[1]Hu H, He HD, Foley WD,et al. Four multidector-row spiral CT: Image quality and volume coverage speed. Radiology, 2000, 215:55 被引量:1
  • 10[2]Rubin GD, Shiau MC, Leung AN,et al. Aorta and iliac arteries: Single versus multiple detector-row spiral CT angiography. Radiology, 2000, 215:670 被引量:1

共引文献96

同被引文献17

引证文献4

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部