摘要
针对老林窖电站可控硅励磁屏充磁回路分励线圈接线问题导致的事故,分析了原设备存在的问题,并进行了切合实际的改造,改造后运行效果良好。
In accordence with the failure resulted from diverting exciting coil of thyristor exciting circuit in Laolinjiao Power Plant,the problems of the original equipment were analysed,its realistic reform was made and good results of operation were achieved.
出处
《水电与新能源》
2010年第6期48-49,共2页
Hydropower and New Energy
关键词
农村小水电
起励电源开关
分励跳闸线圈
充磁回路
small hydropower plant in village
exciting power switch
diverting exciting trip coil
exciting circuit