期刊文献+

适体修饰金纳米粒子光度法检测铅(Ⅱ) 被引量:5

Spectrophotometric detection of lead(Ⅱ) using aptamer modified nanogold particles
下载PDF
导出
摘要 用适体(aptamer)修饰6 nm金纳米粒子制备了检测铅离子的核酸适体-金纳米粒子探针。在pH7.0的Na2HPO4-NaH2PO4缓冲溶液及NaCl介质中,该探针亦不聚集。Pb2+与探针中的aptamer可形成非常稳定的G-四分体结构,并释放出金纳米粒子。在NaCl作用下,释出的金纳米粒子聚集形成较大的金纳米粒子聚集体,导致516 nm处的吸光度降低。Pb2+浓度在0.3~10 nmol/L范围与516 nm处吸光度降低值呈线性关系,其线性回归方程为ΔA=0.0260ρ+0.01,相关系数为0.994 3,方法检出限为0.1 nmol/L Pb2+。该法用于废水样分析,结果与石墨炉原子吸收光谱法一致。 The aptamer was used to modify gold nanoparticles of 6 nm to prepare the aptamer-Au probe for determination of lead.In Na2HPO4-NaH2PO4 buffer solution at pH 7.0 and in the presence of NaCl medium,the probe did not aggregate.Upon the addition of Pb2+,a stable G-quadruplex of Pb2+-aptamer would be formed to release gold nanoparticles that aggregated to form larger nanogold clusters that led to absorption at 516 nm decreased considerably.Under the chosen conditions,the decreased absorbence was linear with the Pb2+ concentration in the range of 0.3-10 nmol/L,with equation of linear regression of ΔA= 0.026 0 ρ+0.01,correlation coefficient of 0.994 3,and a detection limit of 0.1 nmol/L Pb 2+.This method was applied to the determination of Pb 2+ in wastewater sample.The results were in agreement with that of the atomic absorption spectrophotometry.
出处 《冶金分析》 CAS CSCD 北大核心 2010年第4期58-61,共4页 Metallurgical Analysis
基金 广西自然科学基金(No.0832260,0991021Z) 广西环境工程与保护评价重点实验室资助项目
关键词 铅(Ⅱ) 适体 金纳米粒子 光度法 lead(Ⅱ) aptamer nanogold particle spectrophotometry
  • 相关文献

参考文献18

  • 1Yusof N A,Ahmad M.A flow-through optical fibre reflectance sensor for the detection of lead ion based on immobilised gallocynine[J].Sensor.Actuat.B-Chem,2003,94,201-209. 被引量:1
  • 2曾静,王晓燕,刘虎生,敦哲,翟蕾,王京宇.CAIS法校正ICP-MS测定血铅浓度及同位素比值基体效应的研究[J].光谱学与光谱分析,2007,27(2):374-377. 被引量:17
  • 3李燕,徐锡金,刘俊晓,郑良楷,陈刚建,陈松建,霍霞.石墨炉原子吸收法检测新生儿胎粪铅水平[J].光谱学与光谱分析,2008,28(2):447-449. 被引量:2
  • 4Chow E,Hibbert D B,Gooding J J.Electrochemical detection of lead ions via the covalent attachment of human angiotensin I to mercaptopropionic acid and thioctic acid self-assembled monolayers[J].Anal.Chim.Acta,2005,543:167-176. 被引量:1
  • 5Laville S,Goueguel C,Loudyi H,et al.Laser-induced fluorescence detection of lead atoms in a laser-induced plasma:An experimental analytical optimization study[J].Spectrochim.Acta B,2009,64:347-353. 被引量:1
  • 6Dragoe D,Spataru N,Kawasaki R,et al.Detection of trace levels of Pb^2+ in tap water at boron-doped diamond electrodes with anodic stripping voltammetry[J].Electrochim.Acta,2006,51:2437-2441. 被引量:1
  • 7Sanchez L R B,Vicente de la Riva B S,Fernandez J M C,et al.Determination of lead and mercury in sea water by preconcentration in a flow injection system followed by atomic absorption spectrometry detection[J].Talanta,2001,55:1071-1078. 被引量:1
  • 8Huang C C,Cao Z,Chang H T,et al.Protein-protein interaction studies based on molecular aptamers by affinity capillary electrophoresis[J].Anal.Chem.,2004,76,6973-6981. 被引量:1
  • 9Hwang J,Nishikawa S.Novel approach to analyzing RNA aptamer-protein interactions:toward further applications of aptamers[J].J.Biomol.Screen,2006,11:599-605. 被引量:1
  • 10German I,Buchanan D D,Kennedy R T.Aptamers as ligands in affinity probe capillary electrophoresis[J].Anal.Chem.,1998,70.4540-4545. 被引量:1

二级参考文献23

共引文献17

同被引文献151

引证文献5

二级引证文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部