期刊文献+

Development of a competitive format sorbent assay for the determination of parathion in water using molecular imprinted polymer as specific sorbent carrier

Development of a competitive format sorbent assay for the determination of parathion in water using molecular imprinted polymer as specific sorbent carrier
下载PDF
导出
摘要 A rapid,simple,and reliable competitive molecular imprinted polymer sorbent assay(MIPSA) was developed and validated for measurement of parathion in water samples.This assay employed a molecular imprinted polymer(MIP) that was synthesized with non-covalent imprinting method as capture reagent and p-aminoparathion conjugate of horseradish peroxidase(para-HRP) as an enzyme label.The assay depended on a competitive binding reaction between the enzyme conjugate and analyte for the binding sites of the MIP.The optimized analysis conditions of 10 ng mL-1 para-HRP and 10 mg mL-1 polymer were found.The assay was acceptable to detect parathion in water samples under the optimized conditions,with a limit of detection of 50 ng mL-1.Mean analytical recoveries of added parathion in water samples ranged from 101.2%to 105%.The precision of the assay was satisfactory; relative standard deviation ranged from 4.3%to 6%. A rapid,simple,and reliable competitive molecular imprinted polymer sorbent assay(MIPSA) was developed and validated for measurement of parathion in water samples.This assay employed a molecular imprinted polymer(MIP) that was synthesized with non-covalent imprinting method as capture reagent and p-aminoparathion conjugate of horseradish peroxidase(para-HRP) as an enzyme label.The assay depended on a competitive binding reaction between the enzyme conjugate and analyte for the binding sites of the MIP.The optimized analysis conditions of 10 ng mL-1 para-HRP and 10 mg mL-1 polymer were found.The assay was acceptable to detect parathion in water samples under the optimized conditions,with a limit of detection of 50 ng mL-1.Mean analytical recoveries of added parathion in water samples ranged from 101.2%to 105%.The precision of the assay was satisfactory; relative standard deviation ranged from 4.3%to 6%.
出处 《Chinese Chemical Letters》 SCIE CAS CSCD 2010年第11期1361-1365,共5页 中国化学快报(英文版)
基金 supported by the Excellent Young Teacher Fund of Anhui Province,China(No.2009SQRZ105) the Dr.Fund of Anhui University of Architecture(No.QD20090905)
关键词 Molecular imprinting Conjugated enzyme Sorbent assay PARATHION Water sample Molecular imprinting Conjugated enzyme Sorbent assay Parathion Water sample
  • 相关文献

参考文献6

  • 1A.R Sergey,V.P.Elena,B.Alessandra,et al.Biosens.Bioelectron.16(2001)701. 被引量:1
  • 2I.Surugiu,L.Ye,E.Yilmaz,et al.Analyst 125(2000)13. 被引量:1
  • 3S.Wang,Z.Xu,G.Fang,et al.J.Agric.Food Chem.57(2009)4528. 被引量:1
  • 4J.S.Tang,M.Zhang,G.H.Cheng,et al.J.Liq.Chromatogr.Related Technol.32(2009)59. 被引量:1
  • 5P.V.Remo,R.B.Edward,O.M.J.Ralph,Agric.Food Chem.30(1982)572. 被引量:1
  • 6J.S.Tang,M.Zhang,G.H.Cheng,et al.J Environ.Sci.Health Part B 43(2008)707. 被引量:1