摘要
以咪唑催化邻苯二甲酸酐酰化的方法测定增强剂IS211的羟值,准确度高,分析误差为50×10-3;方法精密度好,标准偏差小于04,变异系数不大于50×10-3,测定不同批号试样的羟值完全符合商标值,方法快速、简便,适用于常规分析。
An imidazole catalyzed acylation method of phthalic anhydride is applied to the determination of hydroxyl values of reinforcing agent IS211.The analytical error is 5.0×10 -3 .The relative standard deviation of the method is less than 0.04 and its coefficient of variation is not more than 5.0×10 -3 .Hydroxyl values determined in different batch samples meet the design requirement completely.This method is rapid and simple,it is adaptable to conventional analysis.
出处
《固体火箭技术》
EI
CAS
CSCD
1999年第2期75-78,共4页
Journal of Solid Rocket Technology
关键词
固体推进剂
增强材料
羟值
化学分析
solid propellant
reinforcing material +
chemical radical
chemical analysis