期刊文献+

絮凝-Fenton氧化混凝法处理退浆废水的研究 被引量:7

Research on the treatment of desizing wastewater by flocculation-Fenton oxidation + coagulation
下载PDF
导出
摘要 用絮凝-Fenton氧化混凝法处理常州某印染厂的退浆废水,絮凝剂采用自制的聚硅酸硫酸铝(PASS),絮凝处理最佳工艺条件:30℃,废水初始pH为5~10,絮凝剂投加质量浓度为22.5 g/L,最佳条件下COD去除率可达38.8%。采用Fenton氧化混凝法进行二级处理,较优的工艺参数为:pH为3~5,n(H2O2)∶n(Fe2+)=2∶1,H2O2投加量为0.15 mol/L,PAM的投加质量浓度为1.75~2.25 mg/L。两步处理后总的COD去除率可达90%左右,B/C由原来的0.11升到0.32。 Flocculation-Fenton oxidation + coagulation process has been used for treating the desizing wastewater which is from a printing dying plant in Changzhou.The self-made PASS is used as flocculant.The optimum flocculation conditions have been obtained as follows:the temperature is 30 ℃,initial pH is about 5-10,and dosage of flocculant is 22.5 g/L,the COD removal rate is up to 38.8%.The second step Fenton oxidation + coagulation treatment has been used for getting better technical parameters as follows:pH 3-5,n(H2O2)∶n(Fe2+)=2∶1,the dosage of H2O2 is 0.15 mol/L,and PAM is 1.75-2.25 mg/L.After the treatment,the total COD removal rate can be as high as 90% or so,and B/C rised from 0.11 to 0.32.
作者 邱滔 杨欢
出处 《工业水处理》 CAS CSCD 北大核心 2010年第11期28-31,共4页 Industrial Water Treatment
关键词 退浆废水 聚乙烯醇 聚硅酸硫酸铝 絮凝 FENTON氧化 混凝 desizing wastewater polyvinyl alcohol poly aluminium sulfate silicate flocculation Fenton oxidation coagulation
  • 相关文献

参考文献10

二级参考文献36

共引文献334

同被引文献71

引证文献7

二级引证文献18

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部