期刊文献+

离子交换高效液相层析法与酶化学法测定糖化血红蛋白的比对分析 被引量:14

The comparison analysis of glycosylated hemoglobin detection by ion exchange high performance liquid chromatography and enzymatic method
下载PDF
导出
摘要 目的对离子交换高效液相层析(IE-HPLC)法与酶化学法测定糖化血红蛋白(HbA1c)进行方法学比较。方法依据美国国家临床实验室标准化委员会(NCCLS)有关文件对IE-HPLC法与酶化学法测定HbA1c进行相关性比较、精密度评价。结果 IE-HPLC法与酶化学法测定HbA1c相关性良好(Y=0.962 2X+0.045,r=0.994 0,P〉0.05),预期相对偏差在低值(4.0%)时为2.66%;在中值(6.5%)时为3.09%;在高值(16.0%)时为3.50%。IE-HPLC法批内变异系数(CV)为1.23%~2.17%,批间CV为1.87%~2.99%;酶化学法批内CV为0.93%~1.72%,批间CV为1.65%~2.71%。结论 IE-HPLC法与酶化学法测定HbA1c的相关性、精密度均很好,具有可比性。酶化学法测定HbA1c可用于自动生化分析仪,适合检验科使用。 Objective To compare the ion exchange high performance liquid chromatography(IE-HPLC) and enzymatic method in glycosylated hemoglobin(HbA1c) detection.Methods According to the National Committee for Clinical Laboratory Standards(NCCLS) documents,the correlation and precision of HbA1c detection by IE-HPLC and enzymatic method were compared and analyzed.Results The correlation of HbA1c detection by IE-HPLC and enzymatic method was fine(Y=0.962 2X+0.045,r=0.994 0,P0.05),and the predicted bias was 2.66% at 4.0%,3.09 % at 6.5% and 3.50% at 16.0% respectively.The within-run coefficient of variation(CV) was 1.23%-2.17%,and the between-run CV was 1.87%-2.99% in IE-HPLC.The within-run CV was 0.93%-1.72%,and the between-run CV was 1.65%-2.71% in enzymatic method.Conclusions The correlation and precision of HbA1c detection by IE-HPLC and enzymatic method are fine and comparable.Enzymatic method can be tested by biochemical auto analyzer and applied on automatic diagnosis.
出处 《检验医学》 CAS 北大核心 2010年第11期888-890,共3页 Laboratory Medicine
关键词 糖化血红蛋白 高效液相层析法 酶化学法 比对 Glycosylated hemoglobin High performance liquid chromatography Enzymatic method Comparison
  • 相关文献

参考文献7

  • 1John WG.Glycated haemoglobin analysis[J].Ann Clin Biochem,1997,34(Pt 1):17-31. 被引量:1
  • 2National Committee for Clinical Laboratory Standards.Method comparison and biss estimation using patient samples:approved guideline[S].EP9-A2,NCCLS,2002. 被引量:1
  • 3National Committee for Clinical Laboratory Standards.Evaluation of precision performance of clinical chemistry devices;approved guideline[S].EP5-A,NCCLS,1999. 被引量:1
  • 4冯仁丰主编..临床检验质量管理技术基础[M].上海:上海科学技术文献出版社,2007:428.
  • 5Liu L,Hood S,Wang Y,et al.Direct enzymatic assay for %HbA1C in human whole blood samples[J].Clin Biochem,2008,41(7-8):576-583. 被引量:1
  • 6Frank EL,Moulton L,Little RR,et al.Effects of hemoglo-bin C and S traits on seven glycohemoglobin methods[J].Clin Chem,2000,46(6 Pt 1):864-867. 被引量:1
  • 7王冬环,张传宝,陈文祥,郭健,申子瑜.应重视糖化血红蛋白测定技术及量值溯源[J].中华检验医学杂志,2008,31(9):965-968. 被引量:56

二级参考文献13

  • 1Diabetes Control and Complications Trial Research Group. The effect of intensive treatment of diabetes on the development and progression of long- term complication in insulin-dependent diabetes mellitus. N Engl J Med, 1993, 329: 977-986. 被引量:1
  • 2American Diabetes Assoeiation. Standards of medical care for patients with diabetes mellitus. Diabetes Care, 2003, 26: S33-S50. 被引量:1
  • 3Good.all I, Colman PG, Schneider HG, et al. Desirable performance standards for HbAlc analysis precision, accuracy and standardization. Clin Chem Lab Med, 2007, 45 : 1083-1097. 被引量:1
  • 4Sakurabayashi I, Watano T, Yonehara S, et al. New enzymatic assay for glycohemoglobin. Clin Chem, 2003, 49 : 269-274. 被引量:1
  • 5Little RR, Vesper H, Rohlfing CL, el al. Validalion by a mass speelrometric reference melhod of use of boronate affinily chromalography to measure glycohemoglobin in the presence of hemoglobin S and C traits. Clin Chem, 2005, 51 : 264-265. 被引量:1
  • 6Roberts WL, Safar-Pour S, De BK, et al. Effects of hemoglobin C and S traits on glycohemoglobin measurements by eleven methods. Clin Chem, 2005, 51 : 776-778. 被引量:1
  • 7Bry L, Chen PC, Sacks DB. Effects of hemoglobin variants and .chemically nlodified derivatives on assays for glycohemoglobin. Clin Chem, 2001, 47 : 153-163. 被引量:1
  • 8Little RR, Rohlfing CL, Tennill AL, et al. Effects of sample storage conditions on glycated hemoglobin measurement : evaluation of five different high performance liquid chromatography methods. Diabetes Technol Ther, 2007,9: 36-42. 被引量:1
  • 9Little RR, Rohlfing CL, Wiedmeyer HM, et al. The National Glycohemoglobin Standardization Program: A Five-Year Progress Report. Clin Chem, 2001, 47 : 1985-1992. 被引量:1
  • 10IFCC. Approved IFCC reference melhod for the measuremenl of HbA1c in human blood. Clin Chem Lab Med, 2002, 40: 78-89. 被引量:1