期刊文献+

电感耦合等离子体-原子发射光谱法同时测定铝合金中钴和镍 被引量:5

Simultaneous Determination of Cobalt and Nickel in Aluminium Alloy by Inductively Coupled Plasma Atomic Emission Spectrometry
原文传递
导出
摘要 通过条件实验,确定了电感耦合等离子体-原子发射光谱同时测定铝合金中钴和镍的工作条件,通过基体匹配和背景校正,消除了基体和光谱干扰;建立了电感耦合等离子体-原子发射光谱同时测定铝合金中钴、镍的方法;方法检出限为钴1.25μg/L、镍3.00μg/L,相对标准偏差为钴0.32%、镍0.55%,回收率为钴82.84%—103.4%、镍88.50%—109.0%,该方法简便、快速、检出限低、干扰小、准确可靠,可用于铝合金中钴、镍的同时测定。 Operating parameters of inductively coupled plasma atomic emission spectrometry (ICP-AES) were selected through, parameter experiment. Matrix interference and spectrum interference were eliminated through matrix match and background correction. A method for simultaneous determination of Co and Ni in aluminium alloy by ICP-AES was established. The detection limit of the method was 1. 25ug/L for Co and 3. 00ug/L for Ni, the relative standard difference (RSD) was 0. 32% for Co and 0.55% for Ni. The method recovery rate was 82. 84%-103.4% for Co and 88. 50%--109.0% for Ni. The method was facile, quick, low interferential,accurate and reliable. It could be applied to simultaneous determination of Co and Ni in aluminium alloy.
作者 吴涛 王萍
出处 《光谱实验室》 CAS CSCD 北大核心 2010年第6期2405-2409,共5页 Chinese Journal of Spectroscopy Laboratory
关键词 电感耦合等离子体-原子发射光谱法 铝合金 ICP-AES Aluminium Alloy Co Ni
  • 相关文献

参考文献8

二级参考文献78

共引文献110

同被引文献500

引证文献5

二级引证文献33