期刊文献+

脱硫添加剂在烟气脱硫系统故障处理中的应用 被引量:6

Application of additives on fault treatment of desulfurization system for power plant
下载PDF
导出
摘要 针对某电厂600MW机组石灰石-石膏法烟气脱硫系统脱硫效率下降、石膏中亚硫酸钙含量超标,现场调查分析发现循环泵喷嘴堵塞、浆液喷淋量减少以及系统运行pH值偏高是导致故障发生的主要原因。采用HEE-1型脱硫添加剂进行了处理,结果表明,HEE-1型脱硫添加剂能快速提高系统的脱硫效率,有效地改善脱硫系统的运行工况,促进亚硫酸钙的氧化,可作为脱硫系统故障处理的应急措施。 The fault of desulfurization system about the SO2 removal efficiency losses and the calcium sulphite content in gypsum above standards in 600 MW generator set was analyzed in details.The decrease of slurry spray flux,which was caused by the blockage of circulating pump nozzles and the higher slurry pH value,were the main reasons.The fault was treated by using HEE-1 desulfurization additive.The application results show that the additives presents unique performance,such as raising the desulfurization efficiency quickly,improving the operation conditions of desulphurization system and promoting the oxidation rate of calcium sulphite.HEE-1 desulphurization additive can be used in the fault treatment of the desulfurization system.
出处 《湖南电力》 2010年第5期10-13,共4页 Hunan Electric Power
关键词 脱硫添加剂 烟气脱硫系统 故障处理 应用 desulferization additive desulfurization system fault treatment application
  • 相关文献

参考文献5

二级参考文献31

  • 1刘盛余,张启云,肖文德.湿法烟气脱硫中有机酸添加剂对石灰石的促溶作用[J].华东理工大学学报(自然科学版),2005,31(5):557-562. 被引量:9
  • 2胡金榜,胡玲玲,段振亚,陈志强.湿法烟气脱硫添加剂研究进展[J].化学工业与工程,2005,22(6):456-460. 被引量:23
  • 3ROCHELLE G T,KING C J.The effect of additives on mass transfer in CaCO3 or CaO slurry scrubbing of SO2 from waste gases[J].Iud Eng Chem Fundam,1977,16(1):67-75. 被引量:1
  • 4FREY D D,KING C J.Effects of surfactants on mass transfer during spray drying[J].AIChE Journal,1986,32 (3):437-443. 被引量:1
  • 5王凤东.喷雾干燥法烟气脱硫技术理论与实验研究[D].天津:天津大学,2001. 被引量:2
  • 6Cronkright W A. [J]. Improving Mass Transfer Charateristics of Limestone Slurries by Use of Magnesium Sulfate. Environmental Science & Technology, 1976,10(6):569-572. 被引量:1
  • 7Lani B. Results of ThioClear Testing:Magnesium-Lime FGD with High SO2 Removals and Salable By-products,EPRI,1995 SO2 Control Symposium, Book 2,Session 5B 被引量:1
  • 8Naohiko U, Toru T, Michio O, Tsuyoshi O.[J]. Effects of salts on Limestone Dissolution Rate in Wet Limestone Flue Gas Desulfurization. Environmental Progress. 1993, 12(4): 294-299. 被引量:1
  • 9Charles A A.The Conemaugh Station Phase I Compliance Using Wet Scrubbers,EPRI,1995 SO2 Control Symposium, Book 2,Session 4B 被引量:1
  • 10Chi C T, Lester J H. [J]. Utilization of Adipic Acid Byproducts for Energy Recovery and Enhancement of Flue Gas Desulfurization. Environmental Progress, 1989, 8(4): 223-226. 被引量:1