期刊文献+

The use of contrast-enhanced ultrasound in uterine leiomyomas 被引量:16

The use of contrast-enhanced ultrasound in uterine leiomyomas
原文传递
导出
摘要 Background Ultrasound (US) is a popular method in the diagnosis and treatment of uterine leiomyomas, but the lack of accuracy greatly limits its application. Recently, microbubble enhancement technique affords direct depiction of tumor neovascularity and establishes a more precise vascular map of the tumor. This study was undertaken to describe the distribution patterns of SonoVue, a second-generation contrast agent, in the micrecirculation of uterine leiomyomas, and to investigate the potential use of contrast-enhanced ultrasound (CEUS) in the characterization and treatment of uterine leiomyomas.Methods Ninety-six patients with uterine leiomyomas were enrolled in this study. The CEUS was performed using cadence pulse sequencing technique (CPS) and SonoVue. Enhancement patterns of different lesions were observed.The diagnostic accuracy of CEUS was compared with that of conventional ultrasound.Results After contrast injection, vessels of macro- and micro-circulation of the myoma first appeared, followed by the normal myometrium and finally the endometrium. During the washout phase, the myoma exhibited homogeneous enhancement followed by apparent hypoenhancement. The margin of the tumor was depicted clearly. There was no agent perfusion in the benign degenerative or necrotic area. However in sarcomas degeneration, the feeding vessels appeared markedly earlier than those in myometrium. In addition, the tumor exhibited heterogeneous hyperenhancment with no agent perfusion in the center and no membraniform sign was observed in the late phase. In subserous andsubmucous leiomyomas, the feeding arteries in the pedicle arising from the uterine could be seen. In this study, the diagnostic accuracy of CEUS and conventional US for uterine leiomyomas was 96.7% (160/165) and 82.4% (136/165)respectively.Conclusions CEUS can provide a precise description of the leiomyomas vascularization. The specific enhancement pattern may be helpful for the characterization, treatment choice and therapeutic monitoring of l Background Ultrasound (US) is a popular method in the diagnosis and treatment of uterine leiomyomas, but the lack of accuracy greatly limits its application. Recently, microbubble enhancement technique affords direct depiction of tumor neovascularity and establishes a more precise vascular map of the tumor. This study was undertaken to describe the distribution patterns of SonoVue, a second-generation contrast agent, in the micrecirculation of uterine leiomyomas, and to investigate the potential use of contrast-enhanced ultrasound (CEUS) in the characterization and treatment of uterine leiomyomas.Methods Ninety-six patients with uterine leiomyomas were enrolled in this study. The CEUS was performed using cadence pulse sequencing technique (CPS) and SonoVue. Enhancement patterns of different lesions were observed.The diagnostic accuracy of CEUS was compared with that of conventional ultrasound.Results After contrast injection, vessels of macro- and micro-circulation of the myoma first appeared, followed by the normal myometrium and finally the endometrium. During the washout phase, the myoma exhibited homogeneous enhancement followed by apparent hypoenhancement. The margin of the tumor was depicted clearly. There was no agent perfusion in the benign degenerative or necrotic area. However in sarcomas degeneration, the feeding vessels appeared markedly earlier than those in myometrium. In addition, the tumor exhibited heterogeneous hyperenhancment with no agent perfusion in the center and no membraniform sign was observed in the late phase. In subserous andsubmucous leiomyomas, the feeding arteries in the pedicle arising from the uterine could be seen. In this study, the diagnostic accuracy of CEUS and conventional US for uterine leiomyomas was 96.7% (160/165) and 82.4% (136/165)respectively.Conclusions CEUS can provide a precise description of the leiomyomas vascularization. The specific enhancement pattern may be helpful for the characterization, treatment choice and therapeutic monitoring of l
出处 《Chinese Medical Journal》 SCIE CAS CSCD 2010年第21期3095-3099,共5页 中华医学杂志(英文版)
关键词 ULTRASOUND CONTRAST LEIOMYOMAS UTERINE PATHOLOGY ultrasound contrast leiomyomas uterine pathology
  • 相关文献

参考文献2

二级参考文献60

  • 1耿峰,李国杰.超声造影诊断肾脏疾病的进展[J].临床超声医学杂志,2006,8(7):422-424. 被引量:6
  • 2杜联芳,李凡,姜露莹,许小云,路光中.超声造影在肾占位性病变中的应用[J].中华超声影像学杂志,2006,15(11):813-815. 被引量:69
  • 3牛海燕,简文豪,王红,刘梅,丁桂春.超声造影彩色显像评估肾血流灌注的实验研究[J].中国超声医学杂志,2007,23(2):98-101. 被引量:10
  • 4姜露莹,杜联芳,李凡,伍瑛.肾盂癌超声造影的初步研究[J].中国超声医学杂志,2007,23(2):140-141. 被引量:14
  • 5Taylor KJ,Hilland S.Doppler US.Part I.Basic principles,instrumentation and pitfalls.Radiology 1990;174:297-307. 被引量:1
  • 6Winkler P,Hemke K,Mahl M.Major pitfalls in Doppler investigations.Part Ⅱ.Low flow velocities and color Doppler applications.Pediatr Radiol 1990;20:304-310. 被引量:1
  • 7Bargellini I,Napoli V,Petruzzi P,Cioni R,Vignali C,Sardella S,et al.Type Ⅱ lumbar endoleaks:hemodynamic differentiation by contrast-enhanced ultrasound scanning and influence on aneurysm enlargement after endovascular aneurysm repair.J Vase Surg 2004;41:10-13. 被引量:1
  • 8Bendick PJ,Bore BG,Long GW,Zelenock GB,Brown OW,Shanley CJ.Efficacy of ultrasound scan contrast agents in the noninvasive follow-up of aortic stent grafts.J Vase Surg 2003;37:381-385. 被引量:1
  • 9Napoli V,Bargellini I,Sardella SG,Petruzzi P,Cioni R,Vignali C,et al.Abdominal aortic aneurysm:contrast-enhanced US for missed endoleaks after endoluminal repair.Radiology 2004;233:217-225. 被引量:1
  • 10Catalano O,Lobianco R,Cusati B,Siani A.Contrast-enhanced sonography for diagnosis of ruptured abdominal aortic aneurysm.AIR 2005;184:423-427. 被引量:1

共引文献38

同被引文献64

引证文献16

二级引证文献193

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部