期刊文献+

沉积时间对渗氮类金刚石碳膜表面颜色的影响 被引量:2

Influence of deposition time on chromatics during nitrogen-doped diamond like carbon coating on pure titanium
下载PDF
导出
摘要 目的观察不同沉积时间下应用等离子镀膜法镀制渗氮类金刚石碳膜(N-DLC)的颜色改变规律,以期对临床应用有所指导。方法采用等离子镀膜机在纯钛表面先沉积TiN过渡层,再沉积N-DLC碳膜,通过目测及分光光度测色法对不同沉积时间下(10~80 min,间隔5 min)N-DLC碳膜的颜色进行测定,通过CIE1976 L*a*b*及Mussell表色系统定量评价其色度属性,并结合扫描电镜观察各个沉积时段N-DLC碳膜的表面形貌。结果纯钛表面N-DLC薄膜的颜色与沉积时间有较大关系,沉积时间为30 min时得到较亮的金黄色外观;扫描电镜观察随着沉积时间增加N-DLC碳膜表面逐渐晶化,晶相结构由稳定趋于杂化。结论当镀膜沉积时间为30 min时,可在纯钛表面得到金黄色外观的N-DLC碳膜,此时的晶相结构最稳定。 Objective The aim of this study was to observed the influence of deposition time on chromatics during nitrogen-doped diamond like carbon coating(N-DLC) on pure titanium by multi impulse arc plasma plating machine.Methods Applying multi impulse arc plasma plating machine to produce TiN coatings on pure titanium in nitrogen atmosphere,then filming with nitrogen-doped DLC on TiN in methane(10-80 min in every 5 min).The colors of N-DLC were evaluated in the CIE1976 L*a*b* uniform color scale and Mussell notation.The surface morphology of every specimen was analyzed using scanning electron microscope(SEM) and X-ray photoelectron spectroscopy(XPS).Results When changing the time of N-DLC coating deposition,N-DLC surface showed different color.Golden yellow was presented when deposition time was 30 min.SEM showed that crystallization was found in N-DLC coatings,the structure changed from stable to clutter by varying the deposition time.Conclusion The chromatics of N-DLC coatings on pure titanium could get golden yellow when deposition time was 30 min,then the crystallized structure was stable.
出处 《华西口腔医学杂志》 CAS CSCD 北大核心 2010年第5期543-546,共4页 West China Journal of Stomatology
基金 福建省自然科学基金青年创新基金资助项目(2009D013) 西安工业大学光电工程学院国家薄膜重点实验室开放课题基金资助项目(ZSKJ-200709)
关键词 纯钛 表面改性 类金刚石 色度 结晶 pure titanium surface modification diamond like carbon chroma crystallization
  • 相关文献

参考文献9

  • 1闫召民,郭天文,余建军,潘会波.电解电压对钛阳极氧化色彩的影响[J].实用口腔医学杂志,2001,17(6):530-532. 被引量:12
  • 2Cassinelli C,Morra M,Bruzzone G,et al.Surface chemistry effects of topographic modification of titanium dental implant surfaces:2.In vitro experiments[J].Int J Oral Maxillofac Implants,2003,18(1):46-52. 被引量:1
  • 3尹路,郭天文,王辉,赵雯,弥谦,惠迎雪.纯钛镀制类金刚石薄膜的真菌黏附与细胞毒性研究[J].稀有金属材料与工程,2008,37(1):6-9. 被引量:4
  • 4Thomson-Neal D,Evans GH,Meffert RM.Effects of various prophy-lactie treatments on titanium.Sapphire and hydroxyapatite coated implant:An SEM study[J].Int J Periodont Rest Dent,1989,9(3):300-311. 被引量:1
  • 5尹路,惠迎雪,姚江武.氮硅锆-羟磷灰石涂层应用于纯钛种植体的实验研究[J].华西口腔医学杂志,2009,27(5):492-495. 被引量:3
  • 6Hu A,Alkhesho I,Zhou H,et al.Optical and microstructural properties of diamond-like carbon films grown by pulsed laser deposition[J].Diamond Related Materials,2007,16(1):149-154. 被引量:1
  • 7Qiao ZJ,Li J J,Zhao NQ.Structural evolution and Raman study of nanocarbons from diamond nanoparticles[J].Chemical Physics Letters,2006,429(6):479-482. 被引量:1
  • 8Pal SK,Jiang JC,Meletis EI.Effects of N-doping on the microstructure,mechanical and tribological behavior of Cr-DLC films[J].Surface Coatings Technology,2007,201(25):7917-7923. 被引量:1
  • 9Guerino M,Massi M,Mansano RD.The influence of nitrogen and fluorine on the dielectric constant of hydrogenated amorphous carbon(a-C:H)films[J].Microelectronics J,2007,38(9):915-918. 被引量:1

二级参考文献36

  • 1张新平,于思荣,何镇明.牙科用钛合金研究现状[J].稀有金属材料与工程,2004,33(12):1243-1247. 被引量:11
  • 2熊信柏,李贺军,黄剑锋,李镇江,付业伟.医用碳材料对骨组织的响应及其生物活化改性[J].稀有金属材料与工程,2005,34(4):515-520. 被引量:14
  • 3大田登.色彩工学[M].西安:西安交通大学出版社,1997.. 被引量:7
  • 4高申福 何洁玲.采用阳极氧化工艺对钛制工艺品及钛制器械表面的着色精饰.钛科学与工程.第六届全国钛及钛合金学术交流会文集[M].北京,1987.199. 被引量:1
  • 5Roop KR, Wang M. Functionally graded bioactive coatings of hydroxyapatite/titanium oxide composite system[J]. Materials Letters, 2002, 55 (3) : 133-137. 被引量:1
  • 6Chu CL, Zhu C, Yin ZD, et al. Optimal design and fabrication of hydroxyapatite-Ti asymmetrical functionally graded biomaterial [J]. Materials Science Engineering, 2003, 348(12):244-250. 被引量:1
  • 7Zavanelli RA, Pessanha Henriques GE, Ferreira I, et al. Corrosion-fatigue life of commercially pure titanium and Ti-6Al-4V alloys in different storage environments[J]. J Prosthet Dent, 2000, 84 (3) : 274-279. 被引量:1
  • 8Sun X, Reid JS, Kolawa E, et al. Reactively sputtered Ti-Si-N films Ⅰ. physical properties[J]. J Appl Plays, 1997, 81 (2):656- 663. 被引量:1
  • 9Sun X, Kolawa E, Im S, et al. Effect of Si in reactively sputtered Ti-Si-N films on structure and diffusion barrier performance[J]. J Appl Phys, 1997, 65 (2):43-45. 被引量:1
  • 10Nose M, Zhou M. Properties of Zr-Si-N coatings prepared by RF reactive sputtering [J]. Surface Coatings Technology, 2000, 132(4) : 163-168. 被引量:1

共引文献16

同被引文献16

  • 1Ishihara M,Kosaka T,Nakamura T,et al.Antibacterial activity of fluorine incorporated DLC films[J].Diamond Related Materials,2006,15(8):1011-1014. 被引量:1
  • 2Teughels W,Van Assche N,Sliepen I,et al.Effect of material characteristics and/or surface topography on biofilm development[J].Clin Oral Implants Res,2006,17(Suppl 2):68-81. 被引量:1
  • 3Pereira-Cenci T,Deng DM,Kraneveld EA,et al.The effect of Streptococcus mutans and Candida glabrata on Candida albicans biofilms formed on different surfaces[J].Arch Oral Biol,2008,53(8):755-764. 被引量:1
  • 4Radford DR,Challacombe SJ,Walter JD.Denture plaque and adherence of Candida albicans to denture-base materials in vivo and in vitro[J].Crit Rey Oral Biol Med,1999,10(1):99-116. 被引量:1
  • 5Catalan A,Herrera R,Martinez A.Denture plaque and palatal mucosa in denture stomatitis:Scanning electron microscopic and microbiologic study[J].J Prosthet Dent,1987,57 (5):581-586. 被引量:1
  • 6Keiji K.Effect of surface roughness of porcelain on adhesion bacteria and their synthesizing glucans[J].J Prosthet Dent,2000,83(6):664-667. 被引量:1
  • 7Maitz MF, Gago R, Abendroth B, et al. Hemocompatibility of low- friction boron- carbon- nitrogen containing coatings [J].Biomed Mater Res B Appl Biomater, 2006, 77(1) : 179 -87. 被引量:1
  • 8Harzer W, Schroter A, Gedrange T, et al. Sensitivity of ti tanium brackets to the corrosive influence of fluoride contai ning toothpaste and tea [J]. Angle Orthod, 2001, 71(4) 318-23. 被引量:1
  • 9Sunil K. Pal, Jiechao Jiang,Efstathios I. Meletis. Effects of N-doping on the microstructure, mechanical and tribological behavior of Cr-DLC films [J].Surface and Coatings Tech- nology, 2007, 201(25): 7917-7923. 被引量:1
  • 10Hare Ram Aryal, Sudip Adhikari, Sunil Adhikary, et al. Characteristics of nitrogen doped diamond-like carbon thin films grown by microwave surface wave plasma CVD[J]. Diamond and Related Materials, 2006, 15(11) : 1906-1908. 被引量:1

引证文献2

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部