摘要 目的 评价应用微型外固定支架治疗掌指关节囊内粉碎性骨折的疗效.方法 8例掌指关节囊内粉碎性骨折,其中开放性损伤6例,闭合性损伤2例.采用Orthofix微型外固定支架固定,其中2例同时加用克氏针内固定,2例采用皮瓣覆盖创面.结果 术后平均8周骨折均愈合,未出现关节面不平整或关节间隙狭窄,受伤关节无不稳定.掌指关节活动范围达65°~85°,手握力达健侧80%~90%.结论 应用Orthofix微型外固定支架治疗掌指关节囊内粉碎性骨折,不仅能有效固定关节内的骨折,且大大缩短了骨折端的愈合时间,早期功能锻炼有效地减少了手指的致残率. Objective To evaluate the clinical outcomes of treating intraa-articular comminuted fractures of the metacarpophalangeal joint by mini external fixator. Methods Eight cases of intra-articular comminuted fractures of the metacarpophalangeal joint were treated with Orthofix mini external fixator. Six were open injuries and 2 close injuries. Additional Kirschner wire fixation was done in 2 cases and flap transfer was carried out in 2 cases with severe soft tissue injury. Results All fractures were healed 8 weeks postoperatively. No rough articular surface and narrow joint space occurred. There was no joint instability. The average range of motion of the metacarpophalangeal joint was 65° to 85°. The average grip strength was 80% to 90% of that of the contralateral side. Conclusion Orthofix mini external fixator is an effective way for treatment of intra-articular comminuted fractures of the metacarpophalangeal joint. Not only can it decrease the fracture union time but also allow early postoperative functional rehabilitation which leads to reduced the rate of disability.
出处 《中华手外科杂志》 CSCD 北大核心 2010年第5期291-293,共3页 Chinese Journal of Hand Surgery
基金 上海市浦东新区科技发展基金创新基金资助项目(PKJ2008-Y31)
关键词 掌指关节 骨折 粉碎性 外固定器 Metacarpophalangeal joint Fractures,comminuted External fixators
  • 相关文献

参考文献8

二级参考文献21

  • 1陈山林,田光磊,田文,郜永斌,朱瑾,易传军,郭阳.微型外固定系统在手部骨折中的应用[J].中华骨科杂志,2004,24(8):469-473. 被引量:44
  • 2王华柱,田文,田光磊,李忠哲,薛云皓.有限内固定结合微型外固定架治疗手部骨折[J].中华手外科杂志,2006,22(4):219-220. 被引量:33
  • 3Agce JM.Unstable fracture dislocation of the proximal interphalangeal joint:treatment with a force couple splint.Clin Orthop Relat Res,1987(214):101-112. 被引量:1
  • 4Allison DM.Fractures of the base of the middle phalanx treated by a dynamic external fixation device.J Hand Surg (Br),1996,21(3):305-310. 被引量:1
  • 5Bain GI,Mehta JA,Heptinstall RJ,et al.Dynamic external fixa tion for injuries of the proximal intcrphalangeal joint.J Bone Joint Surg (Br),1998,80(6):1014-1019. 被引量:1
  • 6Khan W,Fahmy N.The S-Quattro in the management of acute intraarticular phalangeal fractures of the hand.J Hand Snrg (Br),2006,31(1):79-92. 被引量:1
  • 7O'Rourke SK,Gaur S,Barton NJ.Long-term outcome of articular fractures of the phalanges:an eleven year follow up.J Hand Surg (Br),1989,14(2):183-193. 被引量:1
  • 8Parsons SW,Fitzgerald JA,Shearer JR.External fixation of unstable metacarpal and phalangeal fractures.J Hand Surg (Br),1992,17(2):151-155 被引量:1
  • 9Strickland JW,Glogovac SV.Digital function following flexor tendon repair in zone Ⅱ:a comparison of immobilization and controlled paasivcd motion techniques.J Hand Surg (Am),1980,5(6):537-543. 被引量:1
  • 10顾玉东.如何治疗手部骨折一评AO微型钢板的应用价值[J].中华手外科杂志,2002,18(2):65-65. 被引量:7

共引文献144

同被引文献77

引证文献12

二级引证文献91

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部