摘要
研制适合中高浓度二氧化氯现场测定的HK-便携式二氧化氯直读比色计,并与五步碘量法及传统分光光度法对二氧化氯测定结果的进行比较,结果表明3种测定方法的结果一致,HK-便携式二氧化氯直读比色计可在现场准确、快速测得结果。
In this paper, HK portable colorimeter(ClO2) was designed for determination of chlorine di-oxide on site. Chlorine dioxide was determined by five-step iodometry, spectrophotometry and HK por- table colorimeter(ClO2) respectively. The results determined by three methods were accordant. HK portable colorimeter(ClO2) can determine ClO2exactly and quickly on site.
出处
《现代仪器》
2010年第5期80-82,共3页
Modern Instruments
基金
广东省技术创新项目(项目编号:200921529)资助项目
关键词
二氧化氯
五步碘量法
分光光度法
便携式比色计
Chlorine dioxide Five-step iodometry Spectrophotometry HK portable colorimeter(ClO2)