摘要
通过对某电站端墙裂缝进行观测,详细分析了裂缝产生原因,针对裂缝的性质总结出一些修复办法和防治措施,以期减少地基不均匀沉降,控制裂缝的产生,确保建筑物的安全和稳定。
Through observing headwall cracks of a power station, it analyzes causes of cracks in detail. In view of the crack nature, it summarizes some repair means and prevention measures, so as to reduce differential settlement of the foundation, and to control crack production, finally to ensure the safety and stability of the building.
出处
《山西建筑》
2010年第30期62-63,共2页
Shanxi Architecture
关键词
端墙
裂缝
沉降观测
沉降量
headwall, crack, settlement observation, total settlement