摘要
根据现场勘察某电厂300 MW 电站锅炉水冷壁燃烧区域腐蚀情况及取样化验结果,对腐蚀原因进行剖析,并提出一些防范措施。
On the basis of surveying the specific condition of corrosion at high temperature in the combustion area of the water-wall of 300 MW boiler in a certain power station as well as simpling and analysis results, the reasons of corrosion at high temperature are analyzed, and some countermeasures are presented in this paper.
关键词
锅炉
水冷壁
高温腐蚀
电站
combustion, water-wall, high temperature corrosion