期刊文献+

头颈部血管DSA介入造影检查技术参数选择的探讨 被引量:1

Technical parameter on the examination of head-cervix vessel DSA
下载PDF
导出
摘要 目的探讨头颈部血管DSA介人造影检查的主要技术参数。方法对2 289例疑似病例行头颈部血管DSA介入造影检查。结果选择适合的技术参数,可以保证头颈部血管DSA介入造影检查的成功率,明显提高血管影像的质量。结论正确调整造影技术参数是保证病人安全,造影成功,提高血管影像质量的主要因素。 Objective To explore the mainly technical parameter on the examination of headcervix digital substractive angiography (DSA). Methods 2 289 patients who suspected with vessel disease were underwent DSA examination. Results By graphic standard, we successfully had DSA examination and got satisfactory graphic quality. Conclusion The ideal selected DSA technical parameter ensured the DSA processing and patienta safety when the conduit reached the goal with the X-ray clairvoyance .
出处 《临床神经外科杂志》 CAS 2010年第3期155-156,共2页 Journal of Clinical Neurosurgery
关键词 头颈部血管 DSA介入造影检查 技术参数 head-cervix vessle DSA technical parameter
  • 相关文献

参考文献4

二级参考文献9

  • 1Marx MV. The radiation dose in interventional radiology study: knowledge brings responsibiligy[J].J Vasc Interv Radiol, 2003, 14(8 ):947-951. 被引量:1
  • 2Vetter S, Schultz FW, Strecker EP, et al. Patient radiation exposure in uterine artery embolization of leiomyomata: calculation of organ doses and effective dose[J].Eur Radiol,2004, 14(2):842-848. 被引量:1
  • 3Bor D, Sancak T, Olgar T, et al. Comparison of effective doses obtained from dose-area product and air kerma measurements in interventional radiology[J].Br J Radiol,2004, 77(4 ):315-322. 被引量:1
  • 4Gkanatsios NA, Huda W, Peters KR. Adult patient doses in interventional neuroradilogy[J].Med Phys,2002, 29(5):717-723. 被引量:1
  • 5Vano E, Goicolea J, Galvan C, et al. Skin radiation injuries in patients following repeated coronary angioplasty procedures[J].Br J Radiol,2001, 74(11 ):1023-1031. 被引量:1
  • 6Onnasch DGW, Schemm A, Kramer HH. Optimization of radiographic parameters for paediatric cardiac angiography[J].Br J Radiol,2004, 77(6): 479-487. 被引量:1
  • 7Kemerink GJ, de Haan MW, Vasbinder GBC, et al. The effect of equipment set up on patient radiation dose in conventional and CT angiography of the renal arteries[J].Br J Radiol,2003, 76(9): 625-630. 被引量:1
  • 8Gkanatsios NA. Effect of radiographic techniques (kVp and mAs) on image quality and patient doses in digital subtraction angiography[J].Med Phys,2002, 29(8):1643-1650. 被引量:1
  • 9Prasad KN, Cole WC, Haase GM. Radiation protection in humans: extending the concept of as low as reasonably achievable (ALARA) from dose to biological damage[J].Br J Radiol,2004, 77(2): 97-99. 被引量:1

共引文献11