目的:探讨密闭式吸痰管更换时间对呼吸机相关肺炎发生的影响。方法:将125例患者随机分为A、B、C三组,A组45例,密闭式吸痰管24小时更换1次,B组48例,密闭式吸痰管48小时更换1次,C组32例,密闭式吸痰管72小时更换1次。结果:三组患者发生呼吸机相关肺炎的例数及时间无统计学差异(P>0.05)。结论:密闭式吸痰管24小时更换1次、48小时更换1次及72小时更换1次对VAP的发生率无影响。但48小时及72小时更换1次,降低患者的住院费用,减轻了社会及患者的医疗负担。
Objective:To detect the influence that replacement of time of closed tracheal suction catheter on ventilator-associated pneumonia.Methods: 125 patients were randomly divided into A,B,C three group,A group 45 patients,closed tracheal suction catheter was changed every 24 hours;B group 48 patients, closed tracheal suction catheter was changed every 48 hours;C group 32 patients,closed tracheal suction catheter was changed every 72 hours.Results:There were no significant differences of the numbers and time of ventilator-associated pneumonia occurrence of the three groups(P〉0.05).Conclusion:The replacement of time of closed tracheal suction catheter at 24 hours,48 patients and 72 hours has no influence on ventilator-associated pneumonia occurrence.But we change the closed tracheal suction catheter every 48 hours or 72 hours will cut down patient's cost of hospitalization,lessan medical burden of society and patient.