电站锅炉一次风管道阻力动态调平方法的研究 被引量:5

Study on Dynamic Leveling Method of Primary Air Piping Resistance of Utility Boilers
下载PDF
导出
摘要 电站锅炉制粉系统送粉管道中广泛采用冷态纯空气阻力调平方法,在纯空气条件下的阻力调平不能保证锅炉实际运行时各送粉管道间的阻力平衡。通过对煤粉空气混合气流造成送粉管道阻力特性改变的原因分析,提出了针对中间储仓式和直吹式制粉系统阻力调平的方法,给出相应的调整计算模型和计算机计算方法。 Cold state pure air resistance leveling method is broadly used in the feeding pipings of utility boilers' pulverized coal preparaption system.Such leveling method can not ensure resistance equilibrium among the pulverized coal feeding pipings during the boiler actual operation.Through analyzing the causes for changes of feeding piping resistance characteristics as a result of pulverized coal air mixture folw,the resistance leveling method of bin storage firing and direct folw type pulverized coal preparation system is put forward with the relevant adjustment calculation model and computer aided calculation method given.
出处 《中国电力》 CSCD 北大核心 1999年第6期28-30,共3页 Electric Power
关键词 一次风量 阻力特性 动态平衡调整 锅炉 电站 primary air piping resistance characteristics cold state equilibrium leveling cold state disequilibrium leveling dynamic equilibrium leveling
  • 相关文献

参考文献5

  • 1岑可法编..锅炉燃烧试验研究方法及测量技术[M].北京:水利电力出版社,1987:317.
  • 2华东电力设计院.输粉系统元件阻力特性试验研究[J].热力发电,1979,(5):5-16. 被引量:5
  • 3哈尔滨锅炉厂(译).煤粉制造设备的计算和设计标准[M].,1958.. 被引量:2
  • 4华绍曾,杨学宁等..实用流体阻力手册[M].北京:国防工业出版社,1985:660.
  • 5热工研究院.制粉系统合理设计布置方法研究报告[M].,1991.. 被引量:1