摘要 目的:评价不同屏胶组合,在不同电压下的成像技术、照片质量、影像特征性表现、肺野内细微结构显示率,并进行千伏效应分析。方法:3种屏胶组合,3种电压进行成人胸部X线摄影。运用诊断学及技术学评审观点,经双育法评审,通过统计学处理。结果:500例胸片肺野内细微结构显示率中,钙屏蓝片100例普通电压为15%;11例准高电压为80%;11例高电压为98%;100例快速屏蓝片准高电压为95%;11例绿屏绿片为11%。经统计学处理,P<0.01,检验有显著意义。结论:1.中速屏蓝片高电压成人胸部X线摄影影像质量,明显优于普通电压及准高电压;2.绿屏绿片高电压成像技术将领先于传统屏胶组合,为传统X线摄影及照片质量开创了一个崭新的技术路线。 Purpose: To evaluate the image-forming Technique under different kilovoltage with different screen-filmcombination. Methods: X-ray films were taken using 3 kinds of screen-film combination and 3 different KV-values. The filmquality, X-ray appearance, details of lung structures were analysed. Results: Of 500 chest filmes, the demonstration rate of finelung pattern was 15% using calcium-screen-blue film combination with conventional KV, 80% with mid-high KV, 98% withhigh KV; 95% using fast-blue film combination with mid-high-KV; 100% with green screen-green film combination. P<0.01.Conclusions: 1. Mid-speed-blue film combination with high KV revealed better chest film quality than with conventional and midhigh KV.2. Green-green-film and high KV combination is superior to conventional screen-film combination.
出处 《放射学实践》 1999年第1期43-45,共3页 Radiologic Practice
关键词 千伏效应 高千伏胸片 影像评价 X线摄影 胸部 Kilovoltage effect High KV chest film Standard of evalvation Green film.