摘要 目的:评价Cerec 3D制作的全瓷冠3年临床效果。方法:选取2006年1月~2006年8月来我院就诊采用Cerec 3D制作的全瓷冠修复的患者99例,共制作105个全瓷冠作为研究对象。同时选取同时期108例患者制作的111个镍镉烤瓷冠为对照组,主要评价全瓷冠和镍镉烤瓷冠的完整性、边缘密合性、边缘染色和牙龈指数。结果:两组修复体在冠完整性方面无统计学差异,Cerec 3D制作的全瓷冠组在边缘密合性、牙龈指数和边缘染色方面优于镍镉烤瓷组。结论:根据本研究结果,Cerec 3D制作的全瓷冠具有临床推广价值。 Objective The authors conducted this investigation to evaluate the practicality and performance of restorations generated by Cerec 3D after three years of clinical service.Methods In this pilot study,the authors checked 105 single-tooth,all-ceramic restorations in 99 patients using Cerec 3D,111 Ni-Cr PFM crowns in 108 patients.These crowns were made from 2006.1~2006.8.Results After three years,there was no any statistically significant influence(P〈0.05) on the clinical performance of the all-ceramic restorations and Ni-Cr PFM crowns on facture of prostheses after three years.The all-ceramic crown was better than Ni-Cr PFM crowns in gingival index(GI),margin sealing and marginal color.Conclusion All-ceramic CAD/CAM-generated restorations are an alternative to conventional restorations.
机构地区 济南市口腔医院
出处 《中国美容医学》 CAS 2010年第8期1208-1209,共2页 Chinese Journal of Aesthetic Medicine
关键词 全瓷冠 CAD-CAM Cerec3D all-ceramic crown CAD-CAM Cerec 3D
  • 相关文献

参考文献10

二级参考文献29

共引文献138

同被引文献11

  • 1Miyazaki T,Hotta Y,Kunii J,et al.A rerview of dental CAD/CAM: current status and future reperspectives from 20 years of experience[J].Dent Mater J,2009,28(1): 44-56. 被引量:1
  • 2Fasbinder DJ,Dennison JB,Heys D,et al.A clinical evaluation of chairside lithium disilicate CAD/CAM crowns: a two-year report [J].J Am Dent Assoc,2010,141(Suppl 2): 10S-14S. 被引量:1
  • 3Vigolo P,Fonzi F.An in vitro evaluation of fit of zirconium-oxide-based ceramic four-unit fixed partial dentures,generated with three different CAD/CAM systems,before and after porcelain firing cycles and after glaze cycles[J].J Prosthodont,2008,17(8): 621-626. 被引量:1
  • 4Jo HY,Hobo PK,Hobo S. Freestanding and multiunit immediate loading of the expandable implant:An upto-40-month prospective survival study[J].{H}Journal of Prosthetic Dentistry,2001,(02):148-155. 被引量:1
  • 5Ericsson I,Nilson H,Lindh T. Immediate functional loading of Branemark single tooth implants.An 18 months'clinical pilot follow-up study[J].{H}Clinical Oral Implants Research,2000,(01):26-33. 被引量:1
  • 6Friberg B,Sennerby L,Meredith N. Comparison between cutting torque and resonance frequency measurements of maxi-llary implants:a 20-month clinical study[J].{H}International Journal of Oral and Maxillofacial Surgery,1999,(04):297-303. 被引量:1
  • 7宿玉成.美学区种植修复的评价和临床程序[J].口腔医学研究,2008,24(3):241-244. 被引量:31
  • 8刘洋,李振春,陈小冬.Cercon CAD/CAM后牙氧化锆全瓷冠桥16例崩瓷原因分析[J].中国实用口腔科杂志,2010,3(6):369-370. 被引量:12
  • 9卢礼,张萍,周燕,汪蕾,武海波,裘松波.椅旁CEREC3D CAD/CAM全瓷修复体临床疗效的初步评价[J].第三军医大学学报,2010,32(20):2239-2241. 被引量:14
  • 10王林虎,郭家平,董青山,王虎中,马毅慧,高群.CEREC全瓷冠在后牙种植修复中的初步研究[J].中国美容医学,2011,20(12):1942-1944. 被引量:1