期刊文献+

溴酚蓝测尿白蛋白方法的试验研究 被引量:2

Study of the Procedure for Determining Albumin in Urine by Bromphenol Blue
下载PDF
导出
摘要 目的:探讨溴酚蓝测定尿白蛋白的方法。方法:利用BM4030自动生化分析仪采用终,权法测定尿白蛋白。结果;该方法的线性高达8g/L。批内变异系数0.5%~4.9%,批间变异系数0.7%~5.8%,回收率96.0%~102%。与抗原抗体法比较,相关方程为Y=0.85+0.978X;r=0.976。结论:可在自动生化分析仪上测定尿微量白蛋白,方法简单易行。 Objective To study the procedure for routine determination of albumin in urine. Methods It is based on the dye-binding properties of albumin with bromphenol blue and BM-4030 type biochemical auto analyzer is used to measure albumin in urine by end -point method. Results Recovery ratio is 96. 3% ~ 101%. Repeated test shows that the within-run CV is 0.5%~4.9% and the between-run CV 0.7%~5.8%. The linear limit is up to 8g/L. Compared with immunochemistry method (Orion Diagnostic reagent) , the method has the correlative equation as follows:Y=2.95+0. 978X, and r=0.978. Conclusiou This method is simple, easy and suit,able for routine determination.
出处 《陕西医学检验》 1999年第2期21-23,共3页 Shaanxi Journal of Medical Laboratory Sciences
关键词 溴酚蓝 白蛋白 自动生化分析仪 Bromphenol blue Albumin Biochemical autoanalyzer
  • 相关文献

参考文献4

二级参考文献3

共引文献102

同被引文献6

引证文献2

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部