期刊文献+

美罗培南及注射用美罗培南HPLC法测定色谱条件的优化 被引量:2

Optimization Assay of Meropenem and Meropenem for Injection by HPLC
下载PDF
导出
摘要 目的:优化美罗培南及注射用美罗培南含量测定的色谱条件。方法:以0.1%三乙胺溶液-乙腈(93.5:6.5)为流动相;以0.1%三乙胺溶液为溶剂;色谱柱为C_(18),柱温30℃;系统适用性检测波长220 nm,检测波长300 nm;调整美罗培南主峰保留时间为5~7 min,流速1.0 ml·min^(-1)。结果:美罗培南的线性范围为50.11~751.68μg·ml^(-1)(r=0.9999);美罗培南平均回收率为101.1%(RSD=1.0%,n=9);注射用美罗培南平均回收率为100.8%(RSD=1.0%,n=9)。结论:本方法灵敏、简便、快速、准确、可用于美罗培南及注射用美罗培南的含量测定。 Objective: To optimize the HPLC chromatographic conditions of meropenem and meropenem for injection. Method: The mobile phase was 0. 1% triethylamine solution-acetomitrele (93.5:6. 5 ), the solvent was 0. 1% triethylamine solution , the ODS- C18 column was used, the column temperature was 30℃ , the system suitability detection wavelength was 220 nm, the detection wavelength was 300 nm, the flow rate was 1.0ml. min- 1 , and the retention time of meropenem was ajusted to 5-7 min. Result: The standard curve of meropenem was linear within the range of 50. 11-751.68 μg·ml^-1 (r = 0. 999 9). The average recovery of meropenem was 101.1% (RSD = 1.0%, n = 9 ), the average recovery of meropenem for injection was 100. 8% (RSD = 1.0%, n = 9 ). Conclusion: This method is sensitive , simple and accurate for determination meropenem and meropenem for injection.
出处 《中国药师》 CAS 2010年第8期1133-1135,共3页 China Pharmacist
关键词 美罗培南 注射用美罗培南 HPLC 含量测定 Meropenem Meropenem for injection HPLC Assay
  • 相关文献

参考文献5

二级参考文献12

  • 1殷果,李玉兰,邓颖,陈美.旋光法测定注射用美罗培南的含量[J].医药导报,2004,23(11):865-866. 被引量:6
  • 2王志立,沈丽君,乔宝笛,胡国新.高效液相色谱法测定兔玻璃体内美罗培南浓度的方法研究[J].实用医学杂志,2005,21(9):894-895. 被引量:3
  • 3Mendez AS, Steppe M, Schapoval EE. Validation of HPLC and UV speetrophotometric methods for the determination of meropenem in pharmaceutical dosage form [ J ] .J Pharm Biomed Anal,2003,33(5) : 947 被引量:1
  • 4Mendez AS, Weisheimer V, Oppe TP, et al. Microbiological assay for the determination of meropenem in pharmaceutical dosage form[J ]. J Pharm Biomed Anal, 2005,37: 649 被引量:1
  • 5al-Meshal MA, Ramadan MA, Lotfi KM, et al. Determination of meropenem in plasma by high - performance liquid chromatography and a microbiological method[J ]. J Clin Pharm Ther, 1995,20(3) : 159 被引量:1
  • 6Elkhaili H, Niedergang S, Pompei D, et al.High - performance liquid chromatographic assay for meropenem in serum [J ]. J Chromatogr B Biorned A ppl , 1996,686(1) : 19 被引量:1
  • 7Niwa T, Nakamura A, Kato T, et al. Pharmacokinetic study of pleural fluid penetration of carbapenem antibiotic agents in chemical pleurisy[ J ]. Respir Med, 2006,100 (2) : 324 被引量:1
  • 8Bompadre S,Ferrante L,De Martinis M, et al .Determination of meropenem in serum by high - performance liquid chromatography with column switching[J ] .J Chromatogr A, 1998,812(1 - 2) :249 被引量:1
  • 9Ehrlich M, Daschner FD, Kummerer K. Rapid antibiotic drug monitoring: Meropenem and ceftazidime determination in serum and bronchial secretions by high - performance liquid chromatography-integrated sample preparation[J] .J Chromatogr B Biomed Sci Appl , 2001, 751( 2 ) : 357 被引量:1
  • 10Mrestani Y,Neubert R,Nagel F.Capillary zone electrophoresis determination of meropenem in biological media using ahigh sensitivity cell[J] .J Pharm Biomed Anal, 1999,20(6) :899 被引量:1

共引文献401