移动床生物膜反应器处理石化废水填料填充率的确定 被引量:4

Determination of Packing Percentage on Treatment of Refinery Wastewater with Moving Bed Biofilm Reactor
下载PDF
导出
摘要 考察了移动床生物膜反应器(MBBR)处理石化废水时在相同水力停留时间下,不同填充率对污染物去除率和氧传递速率的影响。结果表明,填料填充率为30%时,污染物COD和氨氮去除率达最大值,其中COD去除率达90.98%;氧总传递系数12.66,是无填料时的1.48倍;温度20℃时氧传递系数达10.98,是无填料时的1.44倍。因而在MBBR处理石化废水时,适宜的填料填充率为30%。 The influences of different packing percentages on removal of pollutants and rate were investigated in the same hydraulic retention time (HRT) when treating refinery the oxygen - transfer wastewater with moving bed biofilm reactor (MBBR). The results indicated when the packing percentage was 30%, the removal rate of COD,and ammonia - nitrogen was the best with the former up to 90.98%, and the total transfer coefficient for oxygen was 12.66 which was 1.48 times of that with empty bed, and the total transfer coefficient was 10.98 at 20 ℃ which was 1.44 times of that with empty bed. So the suitable packing percentage on treatment of refinery wastewater with MBBR was 30%.
出处 《精细石油化工进展》 CAS 2010年第7期32-34,共3页 Advances in Fine Petrochemicals
关键词 移动床生物膜反应器 石化废水处理 填料填充率 moving bed biofilm reactor( MBBR), refinery wastewater treatment, packing percentage
  • 相关文献

参考文献3

二级参考文献33

  • 1胡妙生,徐根良.厌氧生物活性炭流化床处理制药废水[J].中国给水排水,1996,12(4):39-41. 被引量:14
  • 2Andreottola G, Foladori P, Regazzi M ,et al. Experimental comparison between MBBR and activated sludge system for the treatment of municipal wastewater[ J]. Water Science and Technology ,2000,41 (4 - 5 ) :375 - 382. 被引量:1
  • 3φdegaard H, Gisvold B, Strickland J. The influence of carrier size and shape in the moving bed biofilm process [J]. Water Science and Technology,2000,41 (4 -5):383 -391. 被引量:1
  • 4B Rusten,B G Hellstrōm,F Hellstrōm,et al.Pilot Testing and Preliminary Design of Moving Bed Biofilm Reactors for Nitrogen Removal at the FREVAR Wastewater Treatment Plant[J].Wat.Sci.& Tech.,2000,41(4~5):13-20. 被引量:1
  • 5G Andreottola,P Foladori,M Ragazzi.Upgrading of a Small Wastewater Treatment Plant in a Cold Climate Region Using a Moving Bed Biofilm Reactor (MBBR) System[J].Wat.Sci.& Tech.,2000,41(1):177-185. 被引量:1
  • 6B Rusten,Lars J Hem, Hallvard φdegaard. Nitrification of Municipal Wastewater in Moving-bed Biofilm Reactors[J]. Wat. Envir. Res., 1995, 67(1):75-85. 被引量:1
  • 7B Rusten, Lars J Hem, Hallvard φdegaard. Nitrogen Removal from Dilute Wastewater in Cold Climate Using Moving-bed Biofilm Reactors[J]. Wat. Envir. Res., 1995,67(1):65-74. 被引量:1
  • 8Henrik Aspegren, Ulf Nyberg, Bengt Andersson,et al.Post Denitrifiction in a Moving Bed Biofilm Reactor Process[J]. Wat. Sci. & Tech., 1998,38(1):31-38. 被引量:1
  • 9G Pastorelli,Roberto Canziani,Luca Pedrazzi,et al.Phosphorus and Nitrogen Removal in Moving-bed Sequencing Batch Biofilm Reactors[J]. Wat. Sci. & Tech., 1999,40 (4-5):169-176. 被引量:1
  • 10H Helness, H degaard. Biological Phosphorus Removal in a Sequencing Batch Moving Bed Biofilm Reactor[J]. Wat. Sci. & Tech., 1999,40(4-5):161-168. 被引量:1