芭蕉河水电站1号机组调速器失控,从调速器溜负荷、机组开度异常、机组停机减负荷不成功,分析了调速器失控的原因,并提出了处理措施。经处理后,调速器运行正常。
The governor of generator No.1 got out of control in operation,such as loading slipping,guide-vane opening abnormal,fail in unit stopping load reduction.The restoring measures for the governor are described.