重复CT扫描提高运动靶区勾画范围准确性研究 被引量:1

Repeated CT scan in improving the reproducibility of grass tumor volume for moving target
原文传递
导出
摘要 目的 通过运动靶区的模拟,探讨CT扫描对运动肿瘤靶区勾画范围准确性的影响,寻找提高运动靶区准确显示的方法.方法 以不同频率和振幅做简谐运动的靶区在CT机上扫描,每组分别重复扫描24次,然后对组内24次扫描图像每2、3次扫描随机分组融合.在Pinnacle计划系统中勾画靶区,分析运动对靶区沿运动方向长度的影响.结果 随运动幅度增加,CT扫描所得球形靶区最大体积与方形靶区最大长度都增加,球形靶区最小体积与方形靶区最小长度减小.运动频率对靶体积及长度影响较运动幅度小.对静止扫描长度为3.3 cm、运动频率为20和幅度为2 cm的方形运动靶区24次扫描中最大长度5.1 cm是最小长度2.1 cm的2.4倍.对组内24次扫描图像每1、2、3次融合,融合后靶区长度平均值±标准差分别为(3.77±1.20)、(4.18±0.91)、(4.52±0.59)cm.结论 随运动频率和幅度增加,CT扫描图像与靶区整个运动范围偏差增大.随扫描次数增加,融合所得靶区长度逐渐增加.在没有条件采取措施控制靶区运动情况下,重复CT扫描能简便有效地提高运动靶区勾画范围准确性. Objective To find a method to improve the range accuracy of moving target such as peripheral lung tumors, since a single CT snapshot may not be accurate during the treatment process.Methods A simple harmonic motion phantom, embedded with a cube and a circular ball, was used to simulate the tumor motion. Individualized moving targets were scanned 24 times with different amplitudes and frequencies. Then the images were fused from every 1, 2 or 3 sets of CT scans. The GTV volume variation of circular target and the length variation of the cube target along the z axis were contoured and analyzed. Results As motion amplitude increased, the maximum of both circular target volume and cube target length was increased, while the minimum of the factors was decreased. Motion frequency affected the target volume less than amplitude. For a cube target with the length of 3.3 cm at stationary phase, when motion frequencies was 20 and motion amplitude was 2 cm, the maximal length was 2. 4 times of the minimal length (5. 1 cm vs. 2. 1 cm). When it came to the cube target groups fused from every 1,2 and 3 sets of CT scans, the average length and standard deviation were (3.77 ± 1.20) cm, (4.18 ±0. 91)cm and (4.52 ±0. 59) cm, respectively. With the increase of fused scan number, targets became bigger, the standard deviation decreased, and the change of center positions was decreased. Conclusions The motion amplitude, frequency and the number of CT scans are the main factors affecting target definition, though, the optimized scanning phase is not certained. When 4DCT and respiration gating technique are not available,the efficient and practical method to solve this problem is to scan the target three or more times and fuse them in planning system, which will generate a larger, more reproducible GTV volume for moving targets.
出处 《中华放射肿瘤学杂志》 CSCD 北大核心 2010年第4期346-349,共4页 Chinese Journal of Radiation Oncology
关键词 放射疗法 运动靶区 体层摄影术 X线计算机 图像融合 Radiotherapy Moving target Tomography,X-ray computed Imaging fusion
  • 相关文献

参考文献13

  • 1ICRU Report 50.Prescribing,recording,and reporting photon beam therapy.Lundun:ICRU,1993:1-72. 被引量:1
  • 2ICRU Report 62.Prescribing,recording,and reporting photon beam therapy (supplement to ICRU Report 50).Lundun:ICRU,1999:1-52. 被引量:1
  • 3钟仁明,许峰,何垠波,姜庆丰,李晓玉,柏森.用主动呼吸控制提高肺癌图像引导放疗精度[J].中华放射肿瘤学杂志,2007,16(6):432-434. 被引量:10
  • 4Wong JW,Sharpe MB,Jaffray DA,et al.The use of active breathing control (ABC) to reduce margin for breathing motion.Int J Radiat Oncol Biol Phys,1999,44:911-919. 被引量:1
  • 5Hugo G,Campbell J,Zhang T,et al.4D radiotherapy for lung cancer:what is the reduction in lung dose with motion management.? Int J Radiat Oncol Biol Phys,2007,69:133-134. 被引量:1
  • 6Maxim PG,Loo BW Jr,Shirazi H,et al.Quantification of motion of different thoracic locations using four-dimensional computed tomography:implications for radiotherapy planning.Int J Radiat Oncol Biol Phys,2007,69:1395-1401. 被引量:1
  • 7Nill S,Unkelbach J,Dietrich L,et al.Online correction for respiratory motion:evaluation of two different imaging geometries.Phys Med Bio1,2005,50:4087-4096. 被引量:1
  • 8Gagné IM,Robinson DM.The impact of tumor motion upon CT image integrity and target delineation.Med Phys,2004,31:3378-3392. 被引量:1
  • 9姜庆丰,柏森,徐庆丰,王世超,钟仁明.CT模拟确定肺癌靶区体积的影响因素研究[J].中华放射肿瘤学杂志,2007,16(4):300-301. 被引量:1
  • 10van S(o)rnsen de Koste JR,Lagerwaard FJ,Nijssen-Visser MR,et al.Tumor location cannot predict the mobility of lung tumors:a 3D analysis of data generated from multiple CT scans.Int J Radiat Oncol Biol Phys,2003,56:348-355. 被引量:1

二级参考文献40

  • 1姚原,吴国华,林清,夏士安,钱咏梅,舒忠梅.CT模拟定位对肺癌三维适形放疗的影响[J].中华放射肿瘤学杂志,2005,14(3):213-214. 被引量:11
  • 2于金明.中国肿瘤放射治疗学的现状与展望[J].中国临床医生杂志,2005,33(10):2-4. 被引量:7
  • 3Ross CS, Hussey DH, Pennington EC, et al. Analysis of movement of intrathoracic neoplasms using ultrafast computerized tomography. Int JRadiat Oncol Biol Phys, 1990,18:671-677. 被引量:1
  • 4Ekberg L, Holmberg O, Wittgren L, et al. What margins should be added to the clinical target volume in radiotherapy treatment planning for lung cancer? Radiother Oncol, 1998,48:71-77. 被引量:1
  • 5Shimizu SS, Shirato H, Kagel K, et al. Impact of respiratory movement in the computed tomgraphic images of small lung tumors in three-dimensional (3D) radiotherapy. Int J Radiat Oncol Biol Phys,2000,46:1127-1133. 被引量:1
  • 6Seppenwoolde Y, Shirato H, Kitamura K, et al. Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat,measured during radiotherapy. Int J Radiat Oncol Biol Phys,2002,53:822-834. 被引量:1
  • 7Duan J, Shen S, Fiveash JB, et al. Dosimetric effect of respiration-gated beam on IMRT delivery. Med Phys,2003,30:2241-2252. 被引量:1
  • 8Engelsnan M, Damen EMF, Jaeger KD, et al. The effect of breathing and setup errors on the cumulative dose to a lung tumor. Radiother Oncol, 2001,60:95-105. 被引量:1
  • 9O'dell WG, Schell MC, Reynolds D, et al. Dose broadening due to target position variability during fractionated breath-held radiation therapy.Med Phys,2002,29:1430-1437. 被引量:1
  • 10Shinichi M, Masahiro E, Tatsuaki K, et al. Estimating uncertainties of the geometrical range of particle radiotherapy during respiration. Int JRadiat Oncol Biol Phys,2003,56:121-125. 被引量:1

共引文献20

同被引文献20

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部