摘要 应用模拟循环冷却水动态实验,对负硬度与磁化水抑垢效果的关系进行了深入探讨。实验中测得负硬度为2~10毫摩尔/升时,抑垢率为933%~972%。负硬水应用磁水器抑垢效果较好。 A relationship between negative hardness and the susceptibility of restraining scale formation of magnetized water was studied by a dynamic test imitated cyclic cooling water.It is found in the test that when the negative hardness is 2~10 millimol per litre,the rate of restraining scale formation is 93 3~97 2%.The negative hardness water of restraining scale formation applied in instruments producing magnetizing water produces better resullts
机构地区 黑龙江农垦师专
出处 《化学与粘合》 CAS 1999年第1期48-48,56,共2页 Chemistry and Adhesion
关键词 抑垢率 磁化水 负硬度水 水处理 negative hardness rate of restraining scale formation magnetized water.