摘要
通过计算机对规划方案进行风环境模拟分析尚处在探索阶段。该文通过对同济大学文远楼周边建筑风情况模拟,以上海市多年平均气象要素作为初始条件,计算过程中选用Fluent Airpak软件进行流场模拟分析。通过模拟结果分析旋涡、风影区……在建筑周围分布的情况,并分析产生的影响。实验表明,运用Fluent Airpak对建筑物周边的微观气候环境进行模拟具有实际应用价值,并对建筑群规划具有指导意义。
The wind environment simulation analysis on programming scheme by computer is still occupying the exploration stage. Through simulating the Wen Yuan building's peripheral wind environment in Tongji University,and taking the multi-annual mean meteorological element as initial condition,this paper used Fluent Airpak to do a fluency simulation analysis in the computational process. The peripheral distribution of whirlpool,wind shadow zone etc and their influence were analyzed through simulative result. The experiment indicated that it is valuable and instructional for building group scheme to simulate the building's peripheral microscopic climate through Fluent Airpak.
出处
《华中建筑》
2010年第5期29-30,共2页
Huazhong Architecture
基金
国家发明专利批准项目(专利号:2007100383102
200710038309x)
关键词
文远楼
建筑群
布局
风环境
Wen Yuan building
Building group
Layout
Wind environmen