基于4D-CT研究随呼吸运动靶区的剂量分布规律 被引量:11

Research about the Dose Distribution of Moving Targets Based on 4D-CT Image
下载PDF
导出
摘要 目的:基于4D-CT探讨随呼吸运动靶区的受照剂量分布特征及进行个体化精确放疗计划设计方法。材料和方法:患者在自由呼吸状态下进行多床位Cine模式扫描,每个床位Cine扫描持续时间约4s~6s。扫描后,用研究开发的4D-CT图像重建系统对所得图像进行4D-CT、最大密度投影(MIP)和平均密度投影(AIP)重建,生成多相位4D-CT、MIP和AIPCT。将重建图像传入放疗计划系统中,分别以呼气末相4D-CT、AIPCT和MIPCT图像作为基准图像,其它相位4D-CT作为融合图像进行图像配准,在基准图像上勾画靶区并进行放疗计划设计,比较基准图像和融合图像中靶区的剂量分布。结果:当肿瘤靶区位于肺尖时,呼气末相和吸气末相4D-CT中靶区的剂量分布无明显差异;靶区在肺中部和腹部时,在呼气末相4D-CT上设计的放疗计划,其剂量分布不能很好地覆盖吸气末相时的靶区,可能导致靶区漏照射;在MIP和AIPCT上设计的放疗计划,其剂量分布能较好地覆盖呼气末相/吸气末相时的靶区。结论:基于4D-CT能直观地得到不同呼吸相位时靶区的剂量分布,利用MIP和AIPCT可快速实现运动靶区的个体化精确放疗计划设计。 Objective: To study the dose distribution characteristics and individualized precise radiotherapy planning method based on 4D-CT images in the presence of respiration-indnced organ motion. Methods:CT data of patients were acquired under free breathing state in axial cine mode for multiple couch positions. The scanner continuously acquired projection data of patients at each couch position for 4.0 s-6.0 s. A 4D-CT reconstruction system developed in house was used to reconstruct 4D-CT, maximum intensity projection (MIP) CT and average intensity projection (A/P) CT, which were used as the base images or fusion images separately. The target contoures and treatment planning were based on the base images. The dose distribution of targets on base images were compared with that on fused images. Results:When lung tumors were located in the tip, there was no obvious difference of dose distribution in the target area between end-expiratory and end-inspiratory phase 4D-CT images. When the targets were located in the lung and abdominal part, the dose distribution based on the end-expiratory phase 4D-CT couldn't entirely cover the targets in end-inspiratory phase. The dose distribution of treatment planning based on AIP/M/P CT could cover the whole target area in end-expiratory and end-inspiration phases. Conclusions: The dose distribution of motion targets in different respiratory phase can be achieved by using 4D-CT images. The individualized precise radiotherapy planning for moving targets can be implemented by using M/P/AIP CT images.
出处 《中国医学物理学杂志》 CSCD 2010年第3期1825-1828,共4页 Chinese Journal of Medical Physics
基金 广州市属高校科技计划项目(08A008) 广州医学院博士留学回国人员基金项目(2010-1-11)
关键词 肺部肿瘤 放射疗法 4D-CT 最大密度投影CT 平均密度投影CT respiration lung tumour radiotherapy 4D-CT maximum intensity projection (M/P) CT average intensity projection (A/P) CT
  • 相关文献

参考文献11

  • 1Rietzel E,Chen GTY,Choi NC,et al.Four-dimensional Image-based treatment planning:Target volume segmentation and dose calculation in the presence of respiratory motion[J].Int J Radiat Oncol Bioi Phys.2005,61 (5):1535-1550. 被引量:1
  • 2Rietzel E,Liu AK,Karen P,et al.Design of 4D treatment planning target volumes[J].Int J Radiat Oncol Biol Phys.2006,66 (1):287-295. 被引量:1
  • 3van der Geld YG,van Triest B,Verbakel WF,et al.Evaluation of four-dimensional computed tomography-based intensity-modulated and respiratory-gated radiotherapy techniques for pancreatic carcino ma[J].Int J Radiat Oncol Biol Phys,2008,72(4):1215-1220. 被引量:1
  • 4习勉,刘孟忠,邓小武,刘慧,黄晓延,张黎,李巧巧,胡永红,蔡玲,崔念基.应用4D-CT技术确定肝癌内靶体积及相关剂量学研究[J].癌症,2007,26(1):1-8. 被引量:13
  • 5Cai J,Read PW,Baisden JM,et al.Estimation of error in maximal in tensity projection-based internal target volume of lung tumors:a sim ulation and comparison study using dynamic magnetic resonance imaging[J].Int J Radiat Oncol Biol Phys,2007,69(3):895-902. 被引量:1
  • 6Park K,Huang L,Gagne H,et al.Do maximum intensity projection images truly capture tumor motion?[J].Int J Radiat Oncol Biol Phys,2009,73(2):618-625. 被引量:1
  • 7何瀚,包勇,张黎,黄晓延,黄劭敏,王卫华,刘源,陈利,樊卫,陈明,刘孟忠,崔念基,邓小武.四维CT中MIP融合图像的肺癌内靶体积确定[J].中国肿瘤,2007,16(4):267-271. 被引量:21
  • 8Ehler ED,Tome WA.Lung 4D-IMRT treatment planning:an evalua tion of three methods applied to four-dimensional data sets[J].Ra diother OncoL 2008,88(3):319-325. 被引量:1
  • 9Admiraal MA,Schuring D,Hurkmans CW.Dose calculations account ing for breathing motion in stereotactic lung radiotherapy based on 4D-CT and the internal target volume[J].Radiother Oncol,2008,86 (1):55-60. 被引量:1
  • 10张书旭,周凌宏,徐海荣,杨俊,陈光杰,余辉,林生趣.基于相邻图像最相似原理的4D-CT图像重建研究[J].中国医学物理学杂志,2009,26(5):1409-1414. 被引量:7

二级参考文献43

  • 1刘孟忠,王修身,蔡玲,古模发,刘慧,李群,崔念基,张亚奇,李国辉,李锦清.外照射配合肝动脉栓塞治疗不能手术切除的原发性肝癌的临床研究[J].癌症,2005,24(1):82-86. 被引量:8
  • 2张书旭,徐海荣,陈光杰,杨克柽,林生趣,余辉.呼吸运动对靶区三维重建的影响[J].中国医学物理学杂志,2006,23(6):400-404. 被引量:14
  • 3Underberg R W, Lagerwaard F J, Slotman B J, et al. Use of maximum intensity projections (MIP) for target volume generation in 4DCT scans for lung cancer [J]. Int J Radiat Oncol Biol Phys, 2005,63 ( 1 ) : 253-260. 被引量:1
  • 4Engelsman M, Rietzel E, Kooy H M. Four-dimensional proton treatment planning for lung tumors [J]. Int J Radiat Oncol Biol Phys, 2006,64(5) : 1589-1595. 被引量:1
  • 5Wagman R, Yorke E, Ford E, et al. Respiratory gating for liver tumors: use in dose escalation [J]. Int J Radiat Oncol Biol Phys, 2003,55 (3) : 659-668. 被引量:1
  • 6Ten Haken R K, Martel M K, Kessler M L, et al. Use of Veff and iso-NTCP in the implementation of dose escalation protocols [J].Int J Radiat Oncol Biol Phys, 1993,27(3):689-695. 被引量:1
  • 7Lawrence T S, Ten Haken R K, Kessler M L, et al. The use of 3-D dose volume analysis to predict radiation hepatitis[J]. Int J Radiat Oncol Biol Phys, 1992,23(4) :781-788. 被引量:1
  • 8Dawson L A, Normolle D, Baiter J M, et al. Analysis of radiation induced liver disease using the Lyman NTCP model[J]. Int J Radiat Oncol Biol Phys, 2002,53(4):810-821. 被引量:1
  • 9Xu Z Y, Liang S X, Zhu J, et al. Prediction of radiatoninduced liver disease by lyman normal-tissue complication probability model in three-dimensional conformal radiation therapy for primary liver carcinoma [J]. Int J Radiat Oncol Biol Phys, 2006,65( 1 ) : 189-195. 被引量:1
  • 10Baiter J M, Ten Haken R K, Lawrence T S, et al.Uncertainties in CT-based radiation therapy treatment planning associated with patient breathing [J]. Int J Radiat Oncol Biol Phys, 1996,36 ( 1 ) : 167-174. 被引量:1

共引文献40

同被引文献129

引证文献11

二级引证文献41

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部