期刊文献+

胶束增敏双硫腙分光光度法测定痕量铅 被引量:1

Determination of Trace Lead(Ⅱ) by Dithizone Spectrophotometry in the Presence of Micellar Solutions
下载PDF
导出
摘要 用异丙醇作溶剂溶解双硫腙,Tween-20作为增溶剂,在盐酸介质中,双硫腙水相直接光度法测定水中痕量铅。铅与双硫腙配合物的最大吸收波长为480nm,铅离子在0~150μg/L浓度范围内呈线性,相关系数r=0.9962,回收率为99.4%~101.4%。 The reaction of Pb2+ with dithizone was studied in the presence of Tween-20.In the presence of micellar solutions,lead could form complex with dithizone.The maximum absorption of the complex occurred at 480 nm.The linear range of determination is 0~150 μg/L,r=0.996 2.The recovery rate of the method is 99.4%~101.4%.
作者 高应梅 朱薇
出处 《河北化工》 2010年第5期73-74,共2页 Hebei Chemical Industry
关键词 双硫腙 Tween-20 胶束 分光光度法 lead(Ⅱ) dithizone Tween-20 micellar spectrophotometry
  • 相关文献

参考文献2

  • 1GB7470-87,水质铅的测定双硫腙分光光度法[s]. 被引量:1
  • 2Humaira Khan M Jamaluddin Ahmed M Iqbal Bhanger.A simple speetrophotometric method for the determination of trace level lead in biological samples in the presence of aqueous micellar solutlons[J].Speetroseopy , 2006,20:285-297. 被引量:1