期刊文献+

离轴无透镜傅里叶变换数字全息的分辨率分析 被引量:1

Resolution Analysis of Off-axis Lensless Fourier Transform Digital Holography
下载PDF
导出
摘要 基于离轴无透镜傅里叶变换数字全息的原理,分析了影响离轴无透镜傅里叶变换数字全息分辨率的两个重要因素,一是物的大小和记录距离,二是参考点光源的大小.指出在满足三像分离与采样定理的条件下,恰当选择成像区域、记录距离和参考点光源尺度,可提高成像分辨率.在此基础上分别使用线度为2μm、6.5μm和15μm的参考点光源,对USAF1951分辨率板中心的1.0×1.0mm2和1.5×1.5mm2的成像区域,在不同记录距离进行了相应的实验,获得了与理论分析相符的结果,证明了理论分析的正确性. Based on the off-axis lensless Fourier transform digital holography principle,two main determining factors,which effect the imaging resolution of the Fourier transform digital holography are discussed in this paper.One is the recording distance and the size of the object.The other is the size of reference light source.The 1.0×1.0 mm2 and 1.5×1.5 mm2 areas in the center of an USAF 1951 Style Resolution Target serve as the objects.Corresponding experiments are performed employing three reference light sources with the sizes 2 μm,6.5 μm and 15 μm respectively,at different recording distances.Both the theory and the experimental results show that as in meeting three terms (twin images and zero order in reconstructed image) separation from each other and sampling theorem conditions,shortening the recording distance or decreasing scale of the reference light source may improve the system resolution of lensless Fourier transform digital holography of micro object.
出处 《光子学报》 EI CAS CSCD 北大核心 2010年第5期888-892,共5页 Acta Photonica Sinica
基金 国家自然科学基金(60677019)资助
关键词 数字全息 无透镜傅里叶变换 分辨率 参考光源 Digital holography Lensless Fourier transform Resolution Reference light source
  • 相关文献

参考文献14

  • 1DIRKSEN D,DROSTE H,KEMPER B,et al.Lensless Fourier holography for digital holographic interferometry on biological samples[J].Opt & Las Eng,2001,26(3):241-249. 被引量:1
  • 2王华英,王大勇,谢建军,王广俊.显微数字全息中物光波前重建方法研究和比较[J].光子学报,2007,36(6):1023-1027. 被引量:16
  • 3JEONG K,TUREK J J,NOLTE D D.Fourier-domain digital holographic optical coherence imaging of living tissue[J].Appl Opt,2007,46(22):4999-5007. 被引量:1
  • 4POPESU G,DEFLRES L P,VAUGHAN J C,et al.Fourier phase microscopy for investigation of biological structures and dynamics[J].Opt Lett,2004,29(21):2503-2505. 被引量:1
  • 5JEONG K,PENG L,TUREK J J,et al.Fourier-domain holographic optical coherence imaging of tumor spheroids and mouse eye[J].Appl Opt,2005,44(10):1798-1805. 被引量:1
  • 6YUAN C,ZHAI H,WANG X,et al.Lensless digital holography with short-coherence light source for three-dimensional surface contouring of reflecting micro-object[J].Opt Comm,2007,270(2):176-179. 被引量:1
  • 7SEBESTA M,GUSTAFSSON M.Object characterization with refractometric digital Fourier holography[J].Opt Lett,2005,30(5):471-473. 被引量:1
  • 8DIRKSEN D,DROSTEA H,KIMPER B.Lensless Fourier holography for digital holographic interfervemetry on biological sample[J].Opt Las Eny,2001,36:241-249. 被引量:1
  • 9ZHANG F,PEDRINI G,OSTEN W.Reconstruction algorithm for high-numerical aperture holograms with diffraction-limited resolution[J].Opt.Lett,2006,31(11):1633-1635. 被引量:1
  • 10钟丽云,张以谟,吕晓旭,钱晓凡,熊秉衡.数字全息图再现像的分析计算[J].中国激光,2004,31(5):570-574. 被引量:29

二级参考文献48