摘要 为了优化将抗体偶联在二氧化硅试管表面上以便进行丙型肝炎抗原检测的分析系统,本研究通过氨基硅烷的活化作用,在玻璃表面形成活化的氨基,以戊二醛作为化学交联试剂,在已硅化的玻璃表面固定丙肝单克隆抗体,并进行丙肝抗原(HCAg)的测定。结果显示,通过条件优化实验,发现以10%(V/V)的氨基硅烷水溶液处理玻璃试管3h后,再用3%(V/V)的戊二醛水溶液交联丙肝单克隆抗体2h,可以得到固定效果较好,非特异性较低的玻璃载体,对HCAg可测至1μg/L。可见,用该方法制备的玻璃载体可为进一步建立新的HCAg磁性免疫检测系统提供理论和实验依据。 In order to optimize the fabrication of SiO2 tubes immobilized with antibody for hepatitis C virus antigen (HCAg) detection, we formed the activated amino on the surface of SiO2 tubes by using the activation of aminosilane. Then we immobilized the hepatitis C virus (HCV) monoclonal antibody on the surface of SiO2 tubes by using glutaraldehyde as a chemical cross-linker, followed by detecting HCAg. Sequence tests showed that when the SiO2 tubes were treated in 10% (V/V) aminosilane solution and 3% (V/V) glutaraldehyde solution for 3 hours and 2 hours, respectively, the HCV monoclonal antibody had high immobilization efficiency and low nonspecificity, and the HCAg was detected to 1 ng/mL. This experiment can provide principle and experimental data for establishment of HCAg magnetic immunoassay system.
出处 《生物工程学报》 CAS CSCD 北大核心 2010年第4期545-549,共5页 Chinese Journal of Biotechnology
基金 国家高技术研究发展计划(863计划)(No.2007AA03Z315) 首都医学发展科研基金(No.2007-3080)资助~~
关键词 丙肝病毒抗原 丙肝单克隆抗体 共价交联 氨基硅烷 戊二醛 SiO2载体 hepatitis C virus antigen HCV monoclonal antibody covalent immobilization aminosilane glutaraldehyde SiO2 tubes
  • 相关文献

参考文献11

二级参考文献37

  • 1丙型肝炎防治指南[J].临床肝胆病杂志,2004,20(4):197-203. 被引量:735
  • 2费嘉,马文丽,郑文岭.蛋白质芯片在蛋白质组学研究中的作用[J].生命科学,2005,17(2):132-136. 被引量:3
  • 3谢立,陈万荣,张明程,黄德庄,贺立香.丙型肝炎病毒单克隆抗体的制备及其鉴定[J].天津医药,2005,33(8):508-510. 被引量:3
  • 4谢立,黄德庄,时洪波,贺丽香,靳海英.用酶联免疫夹心法测定肝炎患者血清丙型肝炎抗原[J].中华检验医学杂志,2005,28(11):1159-1162. 被引量:15
  • 5Levine CD, Ghalib RH. Assessment of the patient who failed treatment for chronic hepatitis C. Gastroenterol Nurs, 2005, 28 (3 Suppl) : S24-S30. 被引量:1
  • 6Re V, Gallego S, Trevino E, et al. Evaluation of five screening tests licensed in Argentina for detection of hepatitis C virus antibodies. Mere Inst Oswaldo Cruz, 2005, 100(3) : 303-307. 被引量:1
  • 7Fabrizi F, Lunghi G, Aucella F, et al. Novel assay using total hepatitis C virus (HCV) core antigen quantification for diagnosis of HCV infection in dialysis patients. J Clin Microbiol, 2005, 43 ( 1 ) : 414-420. 被引量:1
  • 8Tobler LH, Stramer SL, Lee SR, et al. Performance of ORTHO HCV core antigen and trak-C assays for detection of viraemia in pre-seroconversion plasma and whole blood donors. Vox Sang, 2005, 89(4) : 201-207. 被引量:1
  • 9Tanaka E, Ohue C, Aoyagi K, et al. Evaluation of a new enzyme immunoassay for hepatitis C virus (HCV) core antigen with clinical sensitivity approximating that of genomic amplification of HCV RNA. Hepatology, 2000, 32(2) : 388-393. 被引量:1
  • 10Widell A, Molnegren V, Pieksma F, et al. Detection of hepatitis C core antigen in serum or plasma as a marker of hepatitis C viraemia in the serological window-phase. Transfusion Med, 2002, 12 (2) : 107-113. 被引量:1

共引文献37

同被引文献19

  • 1贺兆发,刘云宝,陆春风,和庆余,李莉,金玉玲.急性心肌梗塞时血清肌红蛋白动态变化的动物及临床实验研究[J].佳木斯医学院学报,1996,19(6):40-42. 被引量:8
  • 2张玉碧,史建伟.cTnI、Mb和CK-MB联合检测在急性心肌梗死诊断中的临床意义[J].陕西医学杂志,2007,36(3):326-328. 被引量:23
  • 3Gaster RS, Hall DA, Nielsen CH, et al. Matrix-insensitive protein assays push the limits of biosensors in medicine. Nat Med, 2009, 15(11): 1327-1333. 被引量:1
  • 4Mark AC, Osterfeld S J, Yu H, et al magnetoresistive-based immunoassay Sensitive giant for multiplex mycotoxin detection. Biosens Bioelectron, 2010, 25(7) :1635 -1639. 被引量:1
  • 5Koets Rapid M, van der Wijk T, van DNA multi-analyte Eemeren JTWM, et al. immunoassay on a magneto-resistance biosensor. Biosens Bioelectron, 2009 24(7): 1893-1898. 被引量:1
  • 6Guilleaume B, Buneβ A, Schmidt C, et al. Systematic comparison of surface coatings for protein microarrays. Proteomics, 2005, 5(18): 4705-4712. 被引量:1
  • 7Choi S, Yang YM, Chae J. Surface plasmon resonance protein sensor using Vorman effect. Biosens Bioelectron, 2008, 24(4): 893-899. 被引量:1
  • 8Li LY, Chen SF, Jiang SY. Protein adsorption on alkanethiolate self-assembled monalayers: nanoscale surface structural and chemical effects. Langmuir, 2003, 19(7): 2974-2982. 被引量:1
  • 9Nikin P, Martyn CD, Mark H, et al. Immobilization of protein molecules onto homogeneous and mixed carboxylate-terminated self-assembled monolayers. Langmuir, 1997, 13(24): 6485-6490. 被引量:1
  • 10Millone MAD, Hamoudi H, Rodriguez L, et al Self-assembly of alkanedithiols on Au(111) from solution effect of chain length and self-assembly conditions Langmuir, 2009, 25(22): 12945-12953. 被引量:1

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部