期刊文献+

机采血小板细菌培养的假阳性结果分析及控制 被引量:3

Analysis and control of the false-positive reaction of the bacteria cultivation of the aphaeresis platelets.
下载PDF
导出
摘要 目的通过分析BacT/ALERT 3D全自动细菌培养系统在机采血小板细菌培养中产生假阳性结果的原因,以采取相应控制措施,降低假阳性率。方法对2005年1月至2009年12月我站采集的机采血小板的细菌培养结果进行回顾性分析。结果共培养了1918份血小板,初次培养阳性反应有6例,占0.31%;确认阳性1份,阳性率为0.05%;假阳性反应5例,假阳性率为0.26%。结论假阳性反应的出现是不可避免的,但只要找出原因,在日常工作中加以控制,就能减少假阳性反应。 Objective To analyze the reasons of the false-positive reaction of the bacteria cultivation in the BacT/ALERT 3D full-automatic germiculture system and then to take relative action to lower the false-positive reaction rate.Methods From Jan.2005 to Dec.2009,a retrospective analysis of the bacteria cultivation result of the aphaeresis platelets collected in our center blood station was performed.Results 1918 platelets had been cultivated.There were 6 cases with the positive reaction in the primary cultivation,accounting for 0.31% ;there was 1 case confirmed positive reaction,with the positive reaction rate of 0.05% ;there were 5 cases with false-positive reaction,with the false-positive reaction rate of 0.26%.Conclusion The false-positive reaction is inevitable,but can be reduced as long as we find out its reason and put them under control in our routine work.
机构地区 珠海市中心血站
出处 《海南医学》 CAS 2010年第9期6-7,共2页 Hainan Medical Journal
基金 广东省珠海市科学技术研究与开发资金项目(珠科(2009)53号 编号16)
关键词 机采血小板 细菌培养 假阳性反应 Aphaeresis platelet Bacteria cultivation False-positive reaction
  • 相关文献

参考文献6

二级参考文献9

  • 1Braude AI. Transfusion reaction from contaminated blood; their recognition and treatment. N Engl J Med, 1958 ;258:1289-1293. 被引量:1
  • 2Lui H, Yuen K, Cheng TS, et al. Reduction of platelet transfusion-associated sepsis by short-term bacterial culture. Vox Sang, 1999;77:1-5. 被引量:1
  • 3Silva MA, Gregory KR, Carr-Greer MA, et al. Summary of the AABB inter organizational task force on bacterial contamination of platelets: fall 2004 impact survey. Transfusion, 2006 ; 46 : 636-641. 被引量:1
  • 4Fang CT, Chambers LA, Kennedy J, et al. Detection of bacterial contamination in apheresis platelet products: American Red Cross experience, 2004. Transfusion, 2005 ;45 : 1845-1852. 被引量:1
  • 5Perez P. Salmi LR. Follea G, et al. Determinants of transfusionassociated bacterial contamination : results of the French BACTHEM Case-Control Study. Transfusion, 2001 ;41:862-872. 被引量:1
  • 6Brecher ME. Means N. Jere CS, et al. Evaluation of an automated culture system for detecting bacterial contamination of platelets: an analysis with 15 contaminating organisms. Transfusion, 2001 ;41 : 477-482. 被引量:1
  • 7Katz L, Macpherson JL, Zuck TF. Yersinia and blood donation Transfusion, 1992 ; 32 : 191. 被引量:1
  • 8蒋燕群,卫国,倪语星.应用全自动血培养仪提高血液、无菌体液培养阳性率[J].中华医学检验杂志,1999,22(2):71-73. 被引量:71
  • 9李新,焦连亭,康淑荷,王志富.细菌在血培养仪上生长曲线的特点分析[J].江西医学检验,2003,21(4):229-232. 被引量:11

共引文献17

同被引文献29

引证文献3

二级引证文献8

相关作者