摘要
无基础的光伏板支架可以节约成本和工期,无地基光伏板支架倾翻力矩的计算需要较为精确的风载数值,而传统的经验数值是否准确设计需要也有待验证。采用Labview编程,使用拉压传感器对光伏板的拉压力进行测试,所得结果再与经验数值对比分析,验证经验数值,为光伏板支架强度设计和光伏板倾翻力矩的计算提供依据。
In order to save cost and duration, no foundation based photovoltaic panels have been proposed, without foundation PV plate bracket tipping moment need a more precise calculation of wind load values, whereas the traditional values of experience to meet the design needs whether it has yet to be verified. In this paper, using Labview to program, using the pull- pressure sensor to test the pulling and pressing on the pbotovoltaic panels and then compared with the experience of numerical analysis and verification experience, values, providing the basis for the strength design of photovoltaic panels and photovoltaic panels tipping moment calculation.
出处
《能源技术》
2010年第2期93-95,共3页
Energy Technology