期刊文献+

镀黑色锡镍合金溶液中氯化镍的光度法测定 被引量:1

Photometric Determination of Nickel Chloride in a Dark Tin-nickel Alloy Plaiting Bath
下载PDF
导出
摘要 在较大的pH值范围内,EDTA与镍离子生成稳定的蓝色络合物,利用这一特性,用EDTA分光光度法测定镀黑色锡镍合金溶液中氯化镍的质量浓度。以水作参比液,在波长590 nm处测定吸光度。实验表明,在pH≈4的条件下,镀液中的氨分子对测定无影响,铜离子和铁离子对测定的影响一般可以忽略不计。本法相对平均偏差为0.71%,回收率为100.4%-100.8%。 EDTA reacts with nickel ion to form stable blue complex within a wide pH range, and making use of this speciality, concentration of nickel chloride in a dark tin -nickel plating bath is determined with EDTA spectrophotometric methods. The determination is carried out at wavelength 590 nm with water as conference solution. Experiments show that the determination isnt affected by ammonia in the plating bath under a condition of pH ≈ 4. Effects of copper ion and iron ion on the determination can be ignored. The relative average deviation for the method is 0.71%, and the percent recovery is 100.4% -100.8%.
作者 郭崇武
出处 《涂装与电镀》 2010年第2期26-27,36,共3页 Painting and Electroplating
关键词 镀锡镍合金 氯化镍 测定 EDTA 分光光度法 dark tin- nickel alloy plating nickel chloride determination EDTA spectrophotometric methods
  • 相关文献

参考文献2

二级参考文献1

  • 1陈国奇.镀镍槽中镍、镁分析误差产生原因[J].电镀与环保,1991,11(2):38-38. 被引量:1

共引文献1

同被引文献6

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...