期刊文献+

磁敏感加权成像的原理及其临床应用

The Principle and Clinical Application of Susceptibility Weighted Imaging
下载PDF
导出
摘要 磁敏感加权成像(SWI)利用各组织磁敏感差异而产生图像对比,在血管性病变及微量出血诊断方面有独特优势。本文对SWI的原理和与之相关的临床应用进行综述。 Susceptibility Weighted Imaging(SWI) uses the difference of susceptibility in different tissues to cause the image contrast, and it has unique advantages in vascular disease and microbleeds diagnosis. In this paper, the principle and clinical application related of SWI will be reviewed.
作者 陈松
出处 《临床医学工程》 2010年第4期153-155,共3页 Clinical Medicine & Engineering
关键词 磁敏感加权成像 脑出血 血管畸形 Susceptibility Weighted Imaging Cerebral hemorrhage Vascular malformation
  • 相关文献

参考文献18

  • 1Yamada N, Imakita S, Sakuma T, et al. Intracranial calcification on gradient-echo phase images: depiction of diamagnetic susceptibility [J] . Radiology, 1996, 198 (1) : 171-178. 被引量:1
  • 2Reichenbach JR, Venkatesan R, Schillinger DJ, et al. Small vesselsin the human brain: MR venography with deoxyhemoglobin as anIntrinsic contrast agent [J] . Radiology, 1997, 204 (1) : 272-277. 被引量:1
  • 3Sehgal V, Delproposto Z, Haddar D, et al. Susceptibility weighted i maging to visualize blood products and improve tumor contrast in the study of brain masses [J] . Journal of Magnetic Resonance Imaging, 2006, 24 (1) : 41-51. 被引量:1
  • 4Sehgal V, Delproposto Z, Haacke EM, et ol. Clinical applications of neuroimaging with susceptibility weighted imaging [ J] . Journal of Magnetic Resonance Imaging, 2005, 22 (4) : 439-450. 被引量:1
  • 5New PFJ, Ojeman RG, Davis KR, et al. MR and CT of occult vascular malformations of the brain [J] . Am J Neuroradiol, 1986, 7:771-779. 被引量:1
  • 6Marchal G, Bosmans H, Fraeyenhoven LV, et al. Intracranial vascular lesions: optimization and clinical evaluation of three-dimensional time-of-fight MR angiography [J] . Radiology, 1990, 175: 443-448. 被引量:1
  • 7Reichenbach JR, Venkatesan R, Schillinger DJ, et al. Small vessels in the human brain: MR venography with deoxyhemoglobin as an intrinsic contrast agent [J] . Radiology, 1997, 204 (1) : 272-277. 被引量:1
  • 8Greer DM, Koroshetz WJ, Cullen S, et ol. Magnetic resonance imaging improves detection of intracerebral hemorrhage over computed tomograpby after intra-arterial thrombolysis [J] . Stroke, 2004, 35: 491- 495. 被引量:1
  • 9Hermier M, Nighoghossian N. Contribution of susceptibility weighted imaging to acule stroke assessment [J] . Stroke, 2004, 35 (8) : 1989- 1994. 被引量:1
  • 10Idbaih A, Boukobza M, Crassard L, et al. MRI of clot in cerebral venous thrombosis: high diagnostic value of susceptibility weighted images [J] . Stroke, 2006, 37 (4) : 991-995. 被引量:1

二级参考文献9

  • 1Haacke EM, Xu Y, Cheng YC, et aL Susceptibility weighted imaging (SWI). Magn Resom Med,2004, 52:612-618. 被引量:1
  • 2Sehgal V, Delproposto Z, Haacke EM, et aL Clinical applicatioru of neuroimaging with susceptibility-weighted imaging(Review). Magn Reson Imaging,2005, 22: 439-450. 被引量:1
  • 3Barbikian T, Freier MC, Tong KA, et al.Susceptibility weighted imaging: neuropsychologic outcome and pediatric head injury. Pediatric Neurol,2005, 33 : 184-194. 被引量:1
  • 4Xu Y, Haacke EM. The role of voxel aspect ratio in determining apparent vascular phase behavior in susceptibility weighted imaging. Magn Reson Imaging , 2006 , 24 : 155-160. 被引量:1
  • 5Rauscher A, Sedlacik J, Barth M, et al. Magnetic susceptibilityweighted MR phase imaging of the human brain. AJNR, 2005, 26:736-742. 被引量:1
  • 6Reichenbach JR, Jonetz-Mentzel J, Filzek C, et al. Highresolution blood oxygenation level-dependent MR venography: a new technique. Neuroradiology, 2001,43:364-369. 被引量:1
  • 7Lee BCP, Vo KD, Kido DK, et al. MR high-resolution blood oxygenation level-dependent venography of occult (low-flow) vascular lesions. AJNR, 1999, 20: 1239-1242. 被引量:1
  • 8Essig M, Reichenbach JR, Schad JR, et al. High-resolution MR venography of cerebral arteriovenous malformations. Magn Reson Imaging , 1999, 17: 1417-1425. 被引量:1
  • 9Wycliffe ND, Chao J, Holshouser BA, et al. Reliability in detection of hemorrhage in acute infarct by a new three-dimensional gradient recalled echo susceptibility weighted imaging technique compared to computed tomography : a retrospective study. J Magn Reson Imaging , 2004, 20:372-377. 被引量:1

共引文献83

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部