摘要
介绍了江苏华电扬州发电有限公司在运行中相继出现了烟气脱硫系统阻力增大而影响系统性能稳定运行的问题。分析了烟气脱硫系统阻力增大对运行影响的原因,采取了相应措施后,烟气阻力减小,能耗降低。
the problem of the resistance increase of flue gas system in units operation of Jiangsu Huadian Yangzhou Power Generation Corporation Limited was introduced,which would have influence on the system stable operation.The reason of the resistance increment of flue gas system was analyzed,and the relevant measures have been adopted,the flue gas system resistance has been decreased,and the energy consumption was reduced.
出处
《华电技术》
CAS
2010年第4期74-77,共4页
HUADIAN TECHNOLOGY
关键词
烟气阻力增大
堵塞
脱硫装置
原因分析
措施
increment of flue gas resistance
blockage
desulphurization equipment
reason analysis
measure