期刊文献+

震后某工号建渣及土壤样品中铀的分析测定

Determination of Uranium in Building Trash and Soil Samples from Earthquake Area
下载PDF
导出
摘要 采用激光荧光法对“5·12”地震后某工号建筑垃圾和土壤样品进行了铀的测定。方法检出下限D.L≤3×10^-1g/mL,相对标准偏差RSD为7.4%,回收率达到86%-109%。对实验数据进行了分析和初步评价,结果表明,该工号所测样品铀含量基本处于天然本底水平。 Uranium in building trash and soil samples from "May 12" earthquake area were determined using laser fluorescence spectrophotometry. The detection limit, relative standard deviation (RSD) and recovery rate were 3×10^-1g/mL, 7.4% and 86% - 109% respectively. The experimental data were analyzed and evaluated initially. The results showed that the uranium content of this location was at the normal level of background.
出处 《四川环境》 2010年第2期20-22,27,共4页 Sichuan Environment
关键词 激光荧光法 标准加入法 Laser fluorescence spectrophotometry uranium standard addition method