摘要 设计了一款可用于触发和自触发的针板型电晕稳定开关,其中针电极直径为2 mm,主间隙距离为10 mm,触发间隙为5 mm。通过静电场的模拟得知其场强的不均匀系数大于7,并且通过大量实验数据得出:开关起晕电压和击穿电压分别为6.8 kV和19.3 kV,由此得知电晕稳定开关的电晕稳定因子为0.55,这说明开关具有较好的电晕稳定性。 A triggered and self-closing rod-plane corona stabilized spark switch is reported. Its rod electrode diameter, main gap and trigger gap are 2 mm, 10 mm and 5 ram, respectively. The degree of field divergence is known to be larger than 7 by simulating electrostatic field of the switch. Experimental results show that, the corona onset voltage and breakdown voltage are 6.8 kV and 19.3 kV, respectively, based on which the corona stabilized factor is caculated to be 0.55. That is, the switch has good corona stabilized performance.
出处 《强激光与粒子束》 EI CAS CSCD 北大核心 2010年第3期545-549,共5页 High Power Laser and Particle Beams
关键词 电晕稳定开关 不均匀系数 电晕 击穿电压 corona stabilized switch degree of field divergence corona breakdown voltage
  • 相关文献

参考文献10

  • 1Harrower J A, MacGregor S J, Tuema F A, et al. A long lifetime, high PRF plasma closing switch[C]//IEE Colloquium-Pulsed Power. 1998, 45:1-4. 被引量:1
  • 2MacGregor S J, Turnbull S M, Tuema F A, et al. Methods of improving the pulse repetition frequency of high pressure gas switches[C]// 10th IEEE International Pulse Power Conference. 1995, 1:249-254. 被引量:1
  • 3MacGregor S J, Turnbull S M, Tuema F A, et al. Enhanced spark gap switch recovery using nonlinear V/p eurves[J]. IEEE Trans Plasma Sci, 1995, 23(4) :784-804. 被引量:1
  • 4Harrower J A, Macgregor S J, Tuema F A. Design considerations in corona stabilised high repetition rate switches[C]//23rd Int Power Modulator Symp. 1998:198-201. 被引量:1
  • 5MacGregor S J, Turnbull S M, Tuema F A, et al. Factors affecting and methods of improving the pulsed repetition frequency of pulse- eharged and DC-charged high-pressure gas switches[J]. IEEE Trans Plasma Sci, 1997, 25(2) :110-117. 被引量:1
  • 6Tuema F A. MacGregor S J, Harrower J A, et al. Corona stabilization for high repetition rate plasma closing switches[C]//11th International Symposium on High Voltage Engineering. 1999:280-284. 被引量:1
  • 7Harrow A, MacGregor S J, Tuema F A. The influence of the critical volume on high repetition rate, corona stabilized switching[C]// 16th IEEE Pulsed Power Conference Digests of Technical Papers. 1999:1162-1166. 被引量:1
  • 8Harrower J A, Tuema F A, MacGregor S J. Critical volume effects on corona stabilised repetitive breakdown[C]./IEE Colloquium-Pulsed Power. 1999:30. 被引量:1
  • 9朱德恒,严璋.高电压绝缘[M].北京:电力工业出版社,1980. 被引量:6
  • 10Koutsoubis J M, MacGregor S J. Effect of gas type on high repetition rate performance of a triggered ,corona stabilised switch[J].IEEE Trans on Dielectrics and Electrical Insulation, 2003, 25(2) : 245-255. 被引量:1