期刊文献+

国电谏壁发电厂8号机主油泵故障分析及处理 被引量:1

ANALYSIS AND DISPOSAL OF TROUBLE OCCURRED ON MAIN OIL PUMP OF UNIT NO.8 IN GUODIAN JIANBI POWER PLANT
下载PDF
导出
摘要 对8号机组主油泵故障及其处理过程进行了介绍。检查分析认为,主油泵故障最主要的原因为发电机轴电压过高并在主油泵处形成轴电流,导致主油泵轴承电腐蚀及磨损,通过采取加强接地碳刷、润滑油过滤和除水等措施,抑制了轴电流对主油泵的侵蚀,取得了较好的效果。 The characters of periodic trouble occurred on the main oil pump of unit no. 8 and its disposal process have been presented. It is believed from inspection and analysis that the main cause leading to trouble of the main oil pump is over -large shaft voltage of the generator,and resulting in shaft current at the location of main oil pump, leading to electric corrosion and abrasion. Through adopting effective measures, the erosion of shaft current to the main oil pump has been restricted,obtaining better effectiveness.
机构地区 国电谏壁发电厂
出处 《热力发电》 CAS 北大核心 2010年第3期93-96,共4页 Thermal Power Generation
关键词 300 MW机组 主油泵 轴电压 电腐蚀 乌金烧熔 磨损 300 MW unit main oil pump shaft voltage babbit burn abrasion