摘要 心输出量(eardiacoutput,co)是反映心脏功能最直接的指标之一,准确监测CO及相关的血流动力学指标对指导临床治疗具有重要意义。超声心输出量监测仪(ultrasonic cardiac outputmonitor,USCOM)是目前较新的一种CO监测仪,具有无创、快速、准确等特点,近年来刚刚投入临床试用,对此技术的优越性还有待于在临床来进一步检验和改进。现就此对国内外相关文献进行综述,以便了解和评定USCOM的临床应用价值。 The cardiac output (CO) is one of the most direct indicators to reflect cardiac function, and it is great significance to monitor accurately CO and related homodynamic parameters for guiding clinical treatment. Ultrasonic cardiac output monitors (USCOM) with non-invasive, rapid and accurate, is relatively a new technology monitoring CO and has just been put into clinical trial recently. The superiority of this technology has yet to be further tested and improved in clinical scenarios.
作者 张继如 张焰
出处 《国际麻醉学与复苏杂志》 CAS 2010年第1期77-79,共3页 International Journal of Anesthesiology and Resuscitation
关键词 超声心输出量监测仪 心输出量 无创 USCOM Cardiac output Non-invasive
  • 相关文献

参考文献14

  • 1Sandham JD, Hull RD, Brant RF, et al. A randomized,controlled trial of the use of pulmonary-artery catheters in high-risk surgical patients. N Engl J Med, 2003, 348(1): 5-14. 被引量:1
  • 2Connors AF Jr, Speroff T, Dawson NV, et ah The effectiveness of right heart catheterization in the initial care of critically ill patients. JAMA, 1996, 276( 11 ) : 889-897. 被引量:1
  • 3Knirseh W, Kretschmar O, Tomaske M, et al. Cardiac output measurement in children: comparison of the Utrasound Cardiac Output Monitor with thermodilution cardiac output measurement. Intensive Care Med, 2008, 34(6): 1060-1064. 被引量:1
  • 4刘琮 余珍珠 刘晓红 等.应用USCOM及超声多普勒监测正常足月新生儿的左心输出量研究.中国小儿急救医学,2007,14. 被引量:4
  • 5Tan HL, Pinder M, Parsons R, et al. Clinical evaluation of USCOM ultrasonic cardiac output monitor in cardiac surgical patients in intensive care unit. Br J Anaesth, 2005, 94(3): 287-291. 被引量:1
  • 6van Lelyvele-Haas LE, van Zanten AR,Borm GF, et al. Clinical validation of the non-invasive cardiac output monitor USCOM-1A in critically ill patients. Eur J Anaesthesiol, 2008, 25(11 ) : 917-924. 被引量:1
  • 7Wong LS, Yong BH, Young KK, et al. Comparison of USCOM ultrasonic cardiac output monitor with puhnomary artery catheter thermodilution in patients undergoing liver transplantation. LiverTranspl, 2008, 14(7): 1038-1043. 被引量:1
  • 8Su BC, Yu HP, Yang MVV, et al. Reliability of a new ultrasonic cardiac output monitor in recipients of living donor liver transplantation. Liver Transpl, 2008, 14(7): 1029-1037. 被引量:1
  • 9Chand R, Mehta Y, Trehan N. Cardiac output estimation with a new Doppler device after off-pump coronary artery bypass surgery.J Cardiothorac Vasc Anesth, 2006, 20(3) : 315-319. 被引量:1
  • 10Arora D,Chand R,Mehta Y,et al. Cardiac output estimation after off-pump coronary artery bypass: a comparison of two different techniques. Ann Card Anaesth, 2007, 10(2): 132-136. 被引量:1

共引文献3

同被引文献81

  • 1赵顺英,李兴旺,江载芳.关注小儿重症肠道病毒71型感染[J].中华儿科杂志,2008,46(6):401-403. 被引量:232
  • 2管向东,寇秋野.感染性休克血流动力学的监测指标[J].创伤外科杂志,2007,9(2):97-99. 被引量:28
  • 3FAKLER U,PAULI CH, BALLING G,et al. Cardiac index moni- toring by pulse contour analysis and thermodilution after pediatric cardiac surgery[ J]. J Thorac Cardiovasc Surg,2007,133 ( 1 ) :224 - 228. 被引量:1
  • 4GALSTYAN G, BYCHININ M,ALEXANYAN M,et al. Compari- son of cardiac output and blood volumes in intrathoracic compart- ments measured by ultrasound dilution and transpulmonary ther- modilution methods[ J ]. Intensive Care Med, 2010,36 ( 8 ) : 2140 -2144. 被引量:1
  • 5HADIAN M, KIN H, SEVERYN D,et al. Cross-comparison of car- diac output trending accuracy of LiDCO, PiCCO, FloTrac and pul- monary artery catheters[ J]. Critical Care, 2010, 14( 11 ) :R212. 被引量:1
  • 6ROS COq:FIS, NEIL MAGEE, DAVID J. Higgins. Haemodynam- ic monitoring with pulse-induced contour cardiac output (PiCCO) in critical care[J]. Intensive and Critical Care Nursing,2003,19 (5) :301 -307. 被引量:1
  • 7HOFER CK, GAUTER MT, RIST A,et al. The accuracy of preload assessment by different transesophageal echocardiographic tech- niques in patients undergoing cardiac surgery [ J ]. J Cardiothorac Vasc Anesth ,2008,22 ( 2 ) :236 - 242. 被引量:1
  • 8van Lelyvele-Haas LE,van Zanten AR,Bonn GF, et al.Clinical validation of the non-invasive cardiac outputmonitor USC0M-1A in critically ill patients [J]. Eur JAnaesthesiol,2008,25(11):917-924. 被引量:1
  • 9Tan HL,Pinder M,Parsons R,et al. Clinical evaluationof USC0M ultrosonic cardiac output monitor in cardiacsurgical patients in intensive care unit[J]. Br J Anaesth,2005,94(3):287-291. 被引量:1
  • 10Wong LS, Yong BH,Young KK, et al. Comparison ofUSC0M ultrasonic cardiac output monitor with pulmo-mary artery catheter thermodilution in patients undergoingliver transplantation [J]. Liver Transpl,2008,14 (7):1038-1043. 被引量:1

引证文献12

二级引证文献55

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部