设计了基于FF现场总线的立体车库监测系统,并依据排队理论,找到了最优化的立体车库车辆存取调度规则,增强了车库故障监测能力且提高了立体车库的整体效率.
In order to improve the fault monitoring capacity and the service level of storing or retrieving car in the tower - type garage, the author has designed the garage monitoring system based on foundation field bus. According to the queuing theory,the optimum queuing strategy has been obtained to improve the overall efficiency of garage. The fault monitoring capacity of the tower - type garage has also been greatly enhanced.
出处
《机械与电子》
2010年第2期57-59,共3页
Machinery & Electronics
关键词
现场总线
立体车库
最优化调度
field bus
tower - type garage
optimum scheduling