摘要 目的探讨双源CT双能量肺灌注成像(DEPI)与核素肺灌注显像诊断实验性急性肺栓塞的价值。方法24只家兔,20只采用股静脉入路注射明胶海绵制成急性肺栓塞模型,另外4只注射生理盐水作为对照组。栓塞后2h行DEPI及核素肺灌注平面显像。以病理结果为金标准,比较两种方法在肺叶基础上诊断急性肺栓塞的准确性。比较增强DEPI图像上栓塞区与正常肺实质的CT值和强化值(Overlay值)。结果对照组DEPI图像表现为大致均匀的黄红色伪彩,栓塞后栓塞区肺灌注图像表现为灌注缺损,核素肺灌注显示栓塞区放射性稀疏或缺损;DEPI和肺灌注平面显像诊断肺栓塞的敏感度、特异度、阳性预测值、阴性预测值分别为100%、97.50%、95.24%、100%;67.50%、81.25%、64.29%、83.33%。增强后栓塞区和非栓塞区CT值及强化值的差异均有统计学意义(P<0.05)。结论与核素肺灌注显像相比,DEPI诊断实验性急性肺栓塞有更高的敏感度和特异度。 Objective To explore the clinical value of dual-energy CT lung perfusion imaging and perfusion scintigraphy in acute pulmonary embolism (PE) rabbit models. Methods Acute PE models were established in 20 rabbits with femoral vein injection of sponge as embolus materials, and 4 rabbits were injected saline as control group. Two hours after embolization, dual-energy CT and perfusion scintigraphy imaging were performed respectively. Taking the pathologicall findings as the reference standards, the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of both imaging methods were compared. CT values and enhancement degree (overlay value) of the embolic areas and normal pulmonary parenchyma were measured in DEPI image after embolization. Results Normal lung was color-coded as homogeneously yellowish red, perfusion scintigraphy displayed rarefaction or absence. The sensitivity, specificity, PPV, NPV of DEPI was 100%, 97.50%, 95.24%, 100%, and of perfusion scintigraphy was 67.50%, 81.25%, 64.29%, 83.33%, respectively. Increased CT values and overlay values of embolism areas in DEPI images were lower than those of normal pulmonary parenchyma (P〈0.05). Conclusion DEPI has higher sensitivity and specificity than perfusion scintigraphy for detection of pulmonary emboli in an acute PE rabbit models.
出处 《中国医学影像技术》 CSCD 北大核心 2010年第2期221-224,共4页 Chinese Journal of Medical Imaging Technology
基金 南京军区南京总医院院内青年基金(Q2008062)
关键词 双能量 灌注成像 肺栓塞 放射性核素显像 模型 动物 Dual energy Perfusion imaging Pulmonary embolism Radionuclide imaging Models, animal
  • 相关文献

参考文献15

  • 1Tunariu N, Gibbs SJ, Win Z, et al. Ventilation perfusion scintigraphy is more sensitive than multideteetor CTPA in detecting chronic thromboembolie pulmonary disease as a treatable cause of pulmonary hypertension. J Nucl Med, 2007,48(5) : 680-684. 被引量:1
  • 2王峰,方纬,鲁锦国,吕滨,褚克维,王道宇,张万春,倪新海,熊长明,柳志红,何作祥.放射性核素肺显像与螺旋CT诊断急性肺栓塞的对比研究[J].中华核医学杂志,2006,26(6):343-345. 被引量:5
  • 3Dunzinger A, Hafner F, Schaffler G, et al. ^99mTc-apcitide scintigraphy in patients with clinically suspected deep venous thrombosis and pulmonary embolism. Eur J Nucl Med Mol Imaging, 2008,35 (11) :2082-2087. 被引量:1
  • 4Pontana F, Faivre JB, Remy Jardin M, et al. Lung perfusion with dual energy multidetector-row CT (MDCT): feasibility for the evaluation of acute pulmonary embolism in 117 consecutive patients. Acad Radiol, 2008,15(12) : 1494-1504. 被引量:1
  • 5赵艳娥,张龙江,卢光明.肺栓塞CT灌注成像的研究进展[J].中国医学影像技术,2008,24(11):1844-1846. 被引量:5
  • 6Thieme SF, Becker CR, Hacker M, et al. Dual energy CT for the assessment of lung perfusion correlation to seintigraphy. Eur J Radiol, 2008,68(3) :369-374. 被引量:1
  • 7Hoey ET, Gopalan D, Ganesh V, et al. Dual energy CT pulmona ry angiography: a novel technique for assessing acute and chronic pulmonary thromboembolism. Clin Radiol, 2009, 64(4) :414-419. 被引量:1
  • 8吴颂红,徐英进,曹艳霞,王彬生,苏剑,张泽明.肺灌注显像与肺动脉造影诊断周围型肺栓塞的实验研究[J].同位素,2007,20(3):140-144. 被引量:1
  • 9Borotoa K, Remy Jardina M, Flohrb T, et al. Thoracic applications of dual-source CT technology. Eur J Radiol, 2008, 68 (3): 375- 384. 被引量:1
  • 10Fink C, Johnson TR, Michaely HJ, et al. Dual energy CT angiography of the lung in patients with suspected pulmonary embolism: initial results. Rofo, 2008,180(10):879-883. 被引量:1