期刊文献+

Quantitative Accuracy Assessment and Optimization of SPECT Geometrical Calibration

Quantitative Accuracy Assessment and Optimization of SPECT Geometrical Calibration
原文传递
导出
摘要 Accurate geometrical calibration is critical to obtaining high resolution and artifact free reconstructed images for modern animal single photon emission computed tomography (SPECT) systems. Although there have been many published works on the calibration of various SPECT systems, few studies have been done to evaluate the efficacy of the proposed calibration methods in a quantitative manner. This paper presents a numerical method to assess both the uniqueness and the quantitative accuracy of SPECT calibration, which is based on analyzing the singular value decomposition (SVD) components of the Jacobian matrix from a least-square cost function of the calibration. The proposed method is firstly validated by applying it to the calibration of a single pinhole SPECT system and comparing the results with those derived using a published method, and is then used to optimize the calibration setup for a slit-slat SPECT system. With the proposed method, a minimum required number of point source projections to achieve the desired calibration accuracy can be estimated and used as figure-of-merit to evaluate the goodness of a calibration setup. An inverse-square relationship between the calibration accuracy and the number of sampled projections is revealed. Optimal calibration setup is determined through an exhaustive search among all the pos- sibilities of point source arrangements under certain conditions. We demonstrate that for the studied system, the best calibration accuracy is achieved by arranging the point source over the edge of FOV with evenly- spaced angular positions. Point source experiments were conducted to validate the proposed method. Accurate geometrical calibration is critical to obtaining high resolution and artifact free reconstructed images for modern animal single photon emission computed tomography (SPECT) systems. Although there have been many published works on the calibration of various SPECT systems, few studies have been done to evaluate the efficacy of the proposed calibration methods in a quantitative manner. This paper presents a numerical method to assess both the uniqueness and the quantitative accuracy of SPECT calibration, which is based on analyzing the singular value decomposition (SVD) components of the Jacobian matrix from a least-square cost function of the calibration. The proposed method is firstly validated by applying it to the calibration of a single pinhole SPECT system and comparing the results with those derived using a published method, and is then used to optimize the calibration setup for a slit-slat SPECT system. With the proposed method, a minimum required number of point source projections to achieve the desired calibration accuracy can be estimated and used as figure-of-merit to evaluate the goodness of a calibration setup. An inverse-square relationship between the calibration accuracy and the number of sampled projections is revealed. Optimal calibration setup is determined through an exhaustive search among all the pos- sibilities of point source arrangements under certain conditions. We demonstrate that for the studied system, the best calibration accuracy is achieved by arranging the point source over the edge of FOV with evenly- spaced angular positions. Point source experiments were conducted to validate the proposed method.
出处 《Tsinghua Science and Technology》 SCIE EI CAS 2010年第1期96-101,共6页 清华大学学报(自然科学版(英文版)
基金 Supported by the Specialized Research Fund for the Doctoral Program of Higher Education (No.SRFDP200800031071) the National Natural Science Foundation of China (No.10675069)
关键词 single photon emission computed tomography (SPECT) geometrical calibration Jacobian matrix singular value decomposition (SVD) slit-slat collimator single photon emission computed tomography (SPECT) geometrical calibration Jacobian matrix singular value decomposition (SVD) slit-slat collimator
  • 相关文献

参考文献6

  • 1Ma T,Yao R,Shao Y.A SVD-based method to assess the uniqueness and accuracy of SPECT geometrical calibration.IEEE Trans.Med.Imag.,2009,28(2):1929-1939. 被引量:1
  • 2Beque D,Nuyts J,Bormans G,et al.Characterization of pinhole SPECT acquisition geometry.IEEE Trans.Med.Imag.,2003,22(5):599-612. 被引量:1
  • 3Beque D,Nuyts J,Suetens P,et al.Optimization of geometrical calibration in pinhole SPECT.1EEE Trans.Med.Imag.,2005,24(2):180-190. 被引量:1
  • 4Shao Y,Yao P,,Ma T,et al.Initial studies of PET-SPECT dual-tracer imaging.In:Rec.IEEE 2007 Nucl.Sci.Syrup.Med.Imag.Conf.2007,6:4198-4204. 被引量:1
  • 5Yao R,Ma T,Shao Y.Lutetium oxyorthosilicate (LSO)intrinsic activity correction and minimal detectable target activity study for SPECT imaging with a lso-based animal PET scanner.Phys.Med.Biol.,2008,53(16):4399-4415. 被引量:1
  • 6Gallant R A.Testing a subset of the parameters of a nonlinear regression model.J.Am.Star.Assoc.,1975,70(352):927-932. 被引量:1