摘要
用高精度热电离质谱(TIMS)铀系法测定碳酸盐标样的年龄,测定结果与α谱仪铀系法进行比较,铀含量和年龄值均吻合。方法对U的回收率可达95%,Th为92%。TIMS铀系法具有样品用量少、测试时间短、精度高的优点。
The age of stalagmite was determined by high precise thermal ionization mass spectrometry (TIMS) with uranium series age method. Uranium content and age of the standard carbonate were in agreement with standard values. The recoveries for U and Th are 95% and 92% respectively. The method has advantages of rapid, high precision and less sample consumed.
出处
《岩矿测试》
CAS
CSCD
北大核心
1998年第4期268-270,共3页
Rock and Mineral Analysis
基金
国家自然科学基金
中国科学院重大科技项目
关键词
热电离质谱
铀系法
碳酸盐
标样
thermal ionization mass spectrometry (TIMS), uranium series age method, carbonate