摘要
针对SF6负荷开关双簧操动机构经常出现合闸打滑的问题,分析了产生合闸打滑的原因,提出了弧面型扣接面的设计是彻底解决机构在合闸操作时打滑的方法,并阐述了其防打滑的原理。经过实践验证,采用弧面型扣接面后合闸打滑现象消失,有助于SF6负荷开关的可靠运行。
In view of the common closing skid problem of double-spring operating mechanism in SF6 load switch, the causation of the problem is analyzed, and the design of camber junction is presented to thoroughly solve the closing skid problem of the mechanism. Corresponding principle is expounded. It is verified in practice that using camber junction can eliminate closing skid and facilitate the reliable operation of SF6 load switch.
出处
《广东电力》
2010年第1期65-68,共4页
Guangdong Electric Power